Laserfiche WebLink
6.6 At the TLS console, set theVapor Polisher to the manual open <br /> (reference Position <br /> VR-203 <br /> 10M Sectfon-16, IOM Section 18, PMC Diagnostic Menus, <br /> PMC Diagnostic Menus). or VR-204 <br /> 7. TEST PROCEDURE <br /> 7.1 Set the inlet test gas flow rate to 15 scfh- Adjust the flow rate as <br /> necessary during the test to Maintain the flow rate Of 14 to 16 Scfh, Start <br /> the stopwatch. Record the start and end flow rates on Form 1. <br /> 7.2 Record the first HC reading three ( ) minutes after starting the stopwatch, <br /> minutes, 3 <br /> Take three (3) more readings one (1) minute apart for a total test time of 6 <br /> 7.3 Record the HC concentration for each minute from minote 3 to 6 on Form <br /> 1, With other required information. All res <br /> shall be recorded as I,< 0.9%,, s less than 0,9% by volume <br /> shall be recorded as U> results <br /> results greater than 0.9% by volume <br /> 0.9%1J. <br /> 7.4 Alternative to Form 1: Districts May require the use of an alternate Form, <br /> Provided it includes the same minimum parameters identified in Form 1. <br /> 7.5 Remove test equipment. Re-install the outlet test port cap by applying <br /> Teflon TM tape to the threads and tighten the cap % inch turn past snug. <br /> Ensure that the 3-way inlet valve is in the normal operating ("Open") <br /> matic <br /> Position. At the TLS console re-set the Vapor Valve to the auto <br /> mode. <br /> 8. RESULTS <br /> If the emission concentration is > 0.9% by Volume DotPMor 50% LEL) <br /> during any part of the test, then the Vapor Polisher(is in compliance <br /> With the Exhibit 2 HC emission requirements, <br /> 9. ALTERNATIVE TEST PROCEDURES <br /> This Procedure shall be conducted assPecified. Modifications to <br /> procedure shall not be used to determine compliance unless priorthis test <br /> wr <br /> approval has been obtained from the ARB Executive Officeritten <br /> , Pursuant to <br /> Section 14 Of Certification Procedure CP-201, <br /> VST Phase It EVR System, Exhibit 12-VR-203-E and VR-204-E <br />