My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2005-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 1:58:57 PM
Creation date
6/23/2020 6:47:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2009
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\15\PR0231404\STIPULATION FOR FINAL JUDGMENT 12-2-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
409
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPOSER CONTAINMENTfJDC) TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure o Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descrintion Diso # 1/2 Diso # 3/4 Diso # 5/6 Ventbox <br />UDC manufacturer <br />Total Containment <br />Total Containment <br />Total Containment <br />Bravo <br />UDC material <br />FRP <br />FRP <br />FRP <br />FRP <br />UDC depth (inches) <br />30" <br />30" <br />30" <br />30" <br />Height from UDC bottom to highest <br />piping penetration <br />13" <br />13" <br />13" <br />12" <br />Height from UDC bottom to lowest <br />electrical penetration <br />5' <br />5" <br />5" <br />6" <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Sensor <br />Sensor <br />Sensor <br />Sensor <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Depth of water level from UDC bottom (in.) <br />16" <br />15" <br />15" <br />17" <br />Wait time for water level to stabilize (hr:min) <br />0:10 <br />0:10 <br />0:10 <br />0:10 <br />Test start time <br />10:07 AM <br />10:07 AM <br />10:07 AM <br />10:32 AM <br />Initial Probe Reading <br />2.0378 <br />1.5833 <br />1.9481 <br />6.7811 <br />Test end time <br />10:22 AM <br />10:22 AM <br />10:22 AM <br />10:47 AM <br />Final Probe Reading <br />2.0378 <br />1.5830 <br />1.9477 <br />6.7805 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (± 0.0000 inches) <br />0.0000 <br />-0.0003 <br />-0.0004 <br />-0.0006 <br />Pass/Fail threshold (±0.0020 inches / } Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />0.0020 <br />FTEST RESULT <br />PASS <br />PASS <br />PASS <br />PASS <br />Comments: <br />© 2006 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.