Laserfiche WebLink
Ah <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209) 468-3433 Web:www.asjg / <br /> ov.or g ehd <br /> r�Ul'>wd0irt, l,1t"( !GEri':�✓ Fl 11iG 6�1 �a76vr ® <br /> Facility Name: Facility Address: Date: <br /> BONFARE MARKET#35* 15 E GRANT LINE RD, TRACY December 06, 2016 <br /> 111-ii �Wwl <br /> UST Syster Qber 'atiots4, _ <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ❑V ❑R ❑COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> H —e:+• `.. - � _.Y � �r IFI ,.n r ".'+' k.' +�" \ - �i '� N� IIP Jr.� <br /> srol Pkv � trg ys <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre--January 1984) ❑V ❑R ❑COS <br /> N1 <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> l <br /> MW 55 <br /> �tic t3 Ccht � "'I <br /> Item# Remarks <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The daily alarm log did not <br /> document the March 15 and 18, 2016 L9 LINLA fill sump piping sump fuel alarms. These records shall be <br /> maintained on site for at least three years. Monitoring records include: (1) date and time of all monitoring or <br /> sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br /> results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br /> equipment, ground water elevations, or other test results; (6) results of inventory readings and reconciliations. <br /> Immediately locate and maintain all maintenance and monitoring records for the last three years on site and submit <br /> copies to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0002915 PR0231404 SCO01 12/06/2016 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 5 Underground Storage Tank Program OIR <br />