My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 3:00:37 PM
Creation date
6/23/2020 6:47:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\15\PR0231404\PERMANENT INJUNCTION & FINAL JUDGMENT 1-15-10.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 7 of 9eco� <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑ Pressure ❑ Vacuum ®Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used:Level Change Indicator Equipment Resolution: 0.0025 <br /> Fill Sump#87 Fill Sump#87 Fill Sump#91 Fill Sump# <br /> SYP <br /> Sump Diameter: 42 in 42 in 42 in <br /> Sump Depth: 42 in 36 in 27 in <br /> Height from Tank Top to Top of 0 in 0 in 0 in <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 9 in 9 in 9 in <br /> Electrical Penetration: <br /> Condition of sump prior to Dry Dry Dry <br /> testing: <br /> Portion of Sump Tested 2"above sump collar 2"above sump collar 2"above sump collar <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Wait time between applying 5 min 5 min 5 min <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: 2:05 PM 1:35 PM 2:10 PM <br /> Initial Reading(Rj): 0 0 0 <br /> Test End Time: 2:35 PM 2:05 PM 2:40 PM <br /> Final Reading(RF): 0 0 0 <br /> Test Duration: 30 min 30 min 30 min <br /> Change in Reading(RF-Ri): 0 0 0 <br /> Pass/Fail Threshold or Criteria: 0.0025 0.0025 0.0025 <br /> Test Result: ® Pass ❑Fail ® Pass ❑;Fail ;® Pass ❑Fail ❑ Pass ❑ Fail <br /> Is there a sensor in the sump? ®Yes ❑No ®Yes [:]No ®Yes [-]No ❑Yes [:]No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes❑No❑NA ®Yes❑No❑NA ®Yes[:]No[—INA ❑Yes❑No❑NA <br /> detected? <br /> Was sensor removed for testing? ®Yes[:]No❑NA ®Yes❑No❑NA ®Yes[:]No❑NA ❑Yes[:]No[—INA <br /> Was sensor properly replaced and ® ❑ <br /> verified functional after testin ? Yes No❑NA ®Yes❑No❑NA ®Yes[:]No[:INA ❑Yes[:]No[:INA <br /> Comments—(include information on repairs made prior to testing, and recommended,follow-up for failed tests) <br /> Fill Sump(s) sensor(s)were tested separately as part of the annual monitor certification test. <br />