My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 3:00:37 PM
Creation date
6/23/2020 6:47:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\15\PR0231404\PERMANENT INJUNCTION & FINAL JUDGMENT 1-15-10.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 6 of 9 eco <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC)TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure ❑ Vacuum ® Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: Level Change Indicator Equipment Resolution: 0.0025 <br /> UDC#1-2 UDC#3-4 UDC#5-6 UDC# <br /> UDC Manufacturer: Unknown Unknown Unknown <br /> UDC Material: Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 30 in 30 in 30 in <br /> Height from UDC Bottom to Top 12 in 12 in 12 in <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 5 in 5 in 5 in <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Dry Dry Dry <br /> testing: <br /> Portion of UDC Tested' 2"above prod.piping 2"above prod.piping 2"above prod.piping <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes[-]No®NA ❑Yes❑No®NA ❑Yes ❑No❑NA <br /> product and water)?" <br /> Turbine shutdown response time See comments See comments See comments <br /> Is system programmed for fail- <br /> safe shutdown? ❑1 es❑No®NA ❑Yes❑No®NA [-]Yes❑No®NA <br /> Was fail-safe verified to be <br /> operational? ❑Yes❑No®NA [:]Yes[-]No®NA ❑Yes❑No®NA <br /> Wait time between applying 5 min 5 min 5 min <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 1:00 PM 1.05 PM 1:10 PM <br /> Initial Reading(Rj): 0 0 0 <br /> Test End Time: 1:30 PM 1:35 PM 1:40 PM <br /> Final Reading(RF): 0 0 0 <br /> Test Duration: 30 min 30 min 30 min <br /> Change in Reading(RF-Ri): 0 0 0 <br /> Pass/Fail Threshold or Criteria: 1 0.0025 0.0025 0.0025 <br /> Test Result: Pass ❑Pail M Pass ❑ Fail Z Pass ❑ Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ®Yes❑No DNA ❑Yes❑No[INA ®Yes❑No[:INA ❑Yes❑No[:INA <br /> Was sensor properly replaced and ❑Yes❑No DNA ®Yes[-]No DNA ®Yes [:]No❑NA [-]Yes❑No DNA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recoinmended,follow-up.for.failed tests) <br /> * UDC sensor(s)were tested separately as part of the annual monitor certification test. <br /> If the entire depth of the UDC is not tested. specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is`'NO"or'NA".the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.