0 0 ec <br />V/ <br />Page 7 of 9 <br />IM I 111 N -1101 ItIrerelim►1l rNMINULT' ► <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Level Change Indicator <br />Equipment Resolution: 0.0025 <br />` Fill Sump # 87` <br />Fill Sump # 87 <br />SYP <br />Fill Sump # 91 <br />Fill Sump # <br />Sump Diameter: <br />42 in <br />42 in <br />42 in <br />Sump Depth: <br />42 in <br />36 in <br />27 in <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />0 in <br />0 in <br />0 in <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />9 in <br />9 in <br />9 in <br />Condition of sump prior to <br />testing: <br />Dry <br />Dry <br />Dry <br />Portion of Sump Tested <br />2" above sump collar <br />2" above sump collar <br />2" above sump collar <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />5 min <br />5 min <br />5 min <br />Test Start Time: <br />9:35 AM <br />10:40 AM <br />9:50 AM <br />Initial Reading (Rj): <br />0 <br />0 <br />0 <br />Test End Time: <br />10:05 AM <br />11:20 AM <br />10:20 AM <br />Final Reading (RF): <br />0 <br />0 <br />0 <br />Test Duration: <br />30 min <br />30 min <br />30 min <br />Change in Reading (RF-Rj): <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />0.0025 <br />0.0025 <br />0.0025 <br />Test Result: <br />®`Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Is there a sensor in the sump? <br />®Yes ❑No <br />®Yes [-]No <br />®Yes ❑No <br />❑Yes [:]No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />®Yes ❑No ❑NA <br />®Yes [:]No [:INA <br />®Yes ❑No ❑NA <br />❑Yes ❑No [—INA <br />Was sensor removed for testing? <br />®Yes [:]No ❑NA®Yes <br />[:]No[—INA <br />❑Yes ❑No ENA <br />Oyes [:]No❑NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®yes ❑No ❑NA <br />®Yes ❑No ❑NA <br />®Yes ❑No ❑NA <br />[:]Yes❑No ❑NA <br />Comments — (include information on repairs made prior to testing, and recommended folloli,-up for failed tests) <br />" Fill Sump(s) sensor(s) were tested separately as part of the annual monitor certification test. <br />