My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 3:00:37 PM
Creation date
6/23/2020 6:47:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\15\PR0231404\PERMANENT INJUNCTION & FINAL JUDGMENT 1-15-10.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2005. The local agency shall review the proposed program of enhanced leak detection within 45 <br />days of submittal or re -submittal. <br />4 This facility has not replaced the secondary containment system. <br />California Code of Regulations (CCR) Section 2637 (b) All monitoring equipment used to <br />satisfy the requirements of this article shall be installed, calibrated, operated and maintained in <br />accordance with manufacturer's instructions, and certified every 12 months for operability, <br />proper operating condition, and proper calibration. <br />4 This Facility has not performed Annual Monitoring Certification. <br />California Code of Regulations (CCR) Section 2636 (f)(4) Monitoring shall be conducted on <br />all underground pressurized piping with secondary containment at least annually at a pressure <br />designated by the equipment manufacturer, provided that the method is capable of detecting a <br />minimum release equivalent to 0.1 gallon per hour defined at 150 percent of the normal <br />operating pressure of the product piping system at the test pressure with at least a 95 percent <br />probability of detection and not more than a 5 percent probability of false alarm. This <br />requirement is waived if the criteria in subsection (g) of this section are met. <br />4 This facility has not performed Annual Line Tightness Test. <br />VI. ATTACHMENTS <br />1. Secondary Containment Test notification letter dated on September 30, 2002. <br />2. Secondary Containment Test notification letter (certified mail) dated on November <br />15, 2002. <br />3. Numerous CUPA newsletters. <br />4. Notification letter of annual monitoring certification, line leak detector test and line <br />tightness test dated on November 25, 2002. <br />5. Secondary Containment Test Result performed on December 21, 2002. <br />6. Inspection report on March 7, 2003. <br />7. Certified mail dated on March 7, 2003. <br />8. A mailed letter from Mr. Milton H. DeLacy of Bonfare Market dated on March 7, <br />2003. <br />9. A letter dated March 12, 2003 stated that Walton Engineer, Inc is retained by Bonfare <br />Market to design, permit and install a new fueling system at the referenced site <br />10. Permit application to replace existing trench system and to remove existing waste oil <br />tank was received on June 16, 2003. <br />11. Deficiency letter of permit application to replace existing trench system. <br />12. Pictures dated on July 22, 2003 indicate that this facility is in operation. <br />13. Approval letter with conditions for replacing trench system and to remove existing, <br />waste oil tank. <br />�� C- ' . <br />Steven C. Shih, REHS <br />BonFare Market #35 4/4. <br />15 E. Grant Line Road, Tracy, CA <br />z -- <br />Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.