My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 3:00:37 PM
Creation date
6/23/2020 6:47:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\15\PR0231404\PERMANENT INJUNCTION & FINAL JUDGMENT 1-15-10.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sagov.org/ehd <br /> ll <br /> Underground Storage Tank Program Inspoction Report <br /> ._, <br /> Facility Name: Facility Address: Date: <br /> TRACY MARKET INC 15 E GRANT LINE RD,TRACY November 30, 2017 <br /> Aq <br /> UST System 06servations <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V o R o COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden o V o R o COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status o V o R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R o COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V o R c COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V o R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V o R c COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V o R o COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements o V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V o R c COS <br /> 331 CCR 2630(d) Secondarily contained piping not maintained to allow liquid to drain into sump o V ❑R ❑COS <br /> 332 CCR 2631(b),2631(d) Primary and/or secondary containment not constructed in accordance with the established standards o V ❑R ❑COS <br /> Single- lledNon Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V o R c COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R c COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R ❑COS <br /> Ofih <br /> . erVlolatons ` <br /> 2010 See below Unlisted General violation o V o R ❑COS <br /> SUMMARY OF YIOLATTIONS <br /> (GLASS 1,CLASS II,or MINOR-No to CoI7 <br /> f <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for tank TA0140403(87 grade),tank TA0140404(87 grade)and tank TA0140405(91 <br /> grade)are not current in CERS. <br /> For all three tanks, under Tank Construction, change"yes"to"no"for Ball Float under the Overfill Protection <br /> category. <br /> For all three tanks, under Vent,Vapor Recovery(VR)and Riser/Fill Pipe Piping Construction, change"none"to <br /> "fiberglass"for Riser Pipe Secondary Containment. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> FA0002915 PR0231404 SCO01 11/30/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.