My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1999-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 1:10:52 PM
Creation date
6/23/2020 6:47:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2011
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1999-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
513
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br />Installing the Containment Sump Sensor Installation Procedures <br />Installation Procedures <br />QInstalling the float in a sump where water or fuel already exists will result in an immediate alarm. <br />Make sure no liquid is present in the containment sump. Failure to comply can result in equipment <br />damage or undetected potential environmental and health hazards. <br />1. Turn OFF power to the TLS Console. <br />2. Make sure no liquid exists in the containment sump. <br />If this is an existing installation where mounting hardware is already in place and only the Containment Sump <br />Sensor is being replaced, omit Step 3. <br />3. Install the mounting hardware according to the instructions provided with the Universal Mounting Kit (see <br />Figure 7). <br />QDo not attach sensor to flexible product line. <br />Co <br />sui <br />Containment* <br />sump sensor <br />"'-�therproof junction <br />with 1/2 -inch N.P.T. <br />ads (16 cubic inch <br />me minimum) <br />*Containment sump sensor should: <br />1. Rest in the lowest point of sump. <br />2. Be positioned as close to outer wall as possible. <br />3. Be mounted in a true vertical position. <br />Seal -off <br />1/2" Rigid conduit <br />o console <br />Product line <br />etc., from <br />Universal sensor mounting kit <br />Figure Z Typical Containment Sump Sensor Installation <br />0 <br />sensors\cssinst.eps <br />This device is installed in equipment where potentially lethal voltages may <br />exist. <br />Electrical shock resulting in serious injury or death may result if power is on <br />during installation and the device is improperly installed. <br />Before installing this device, turn off power to the system. <br />QInstalling the float in a sump where water or fuel already exists will result in an immediate alarm. <br />Make sure no liquid is present in the containment sump. Failure to comply can result in equipment <br />damage or undetected potential environmental and health hazards. <br />1. Turn OFF power to the TLS Console. <br />2. Make sure no liquid exists in the containment sump. <br />If this is an existing installation where mounting hardware is already in place and only the Containment Sump <br />Sensor is being replaced, omit Step 3. <br />3. Install the mounting hardware according to the instructions provided with the Universal Mounting Kit (see <br />Figure 7). <br />QDo not attach sensor to flexible product line. <br />Co <br />sui <br />Containment* <br />sump sensor <br />"'-�therproof junction <br />with 1/2 -inch N.P.T. <br />ads (16 cubic inch <br />me minimum) <br />*Containment sump sensor should: <br />1. Rest in the lowest point of sump. <br />2. Be positioned as close to outer wall as possible. <br />3. Be mounted in a true vertical position. <br />Seal -off <br />1/2" Rigid conduit <br />o console <br />Product line <br />etc., from <br />Universal sensor mounting kit <br />Figure Z Typical Containment Sump Sensor Installation <br />0 <br />sensors\cssinst.eps <br />
The URL can be used to link to this page