My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:36:41 PM
Creation date
6/23/2020 6:47:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. PIPING SUMP TESTING <br /> Test Method Developed By: F]Sump.M.anufacturer 21 Industry Standard ❑Professional Engineer <br /> F]Other(Spew)r <br /> Test Method Used: ❑Pressure ❑Vacuum Hydrostatic <br /> []Other(Sped,fv) <br /> Test Equipment Used: INCON TS-STS Equipment Resolution: 36" <br /> Sump# 1 SUMP# SUMP# SUMP# <br /> Sump Diameter: 36" <br /> Sump Depth: 45" <br /> Sump Material: FIBERGLASS <br /> Height from Tank"Cop to Top of 21 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 17" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: GOOD <br /> Portion of sump'rested' 25" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both []Yes [—]No EINA E]Yes []No [jNA [:]Yes []No EINA Ej Yes ao []NA <br /> product and water)? <br /> Turbine Shutdown response time N/A N/A N/A N!A <br /> Is system programmed for fail-safe [:]Yes FINo EINA FlYes EINEo [INA El Yes [:]No El NA El Yes [3No [INA <br /> shutdown'?` <br /> Was fail-safe verified to be []Yes [:]No E]NA nYLsFINo nNA E]Ycs E]No FINA F1 Yes El No [INA <br /> perational'?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 30 MIN. <br /> test: <br /> 'rest Start Time. 8:54 AM 9:09 AM <br /> Initial Reading(Ri): 5.9068' 5.9066-1 <br /> Test End Time: 9:09 AM 9:24 AM <br /> Final Reading(114 5.9065" <br /> Test Duration: 15 MIN. 15 MIN. <br /> Change in Reading(14-Rj): -0.0002" -0.0001" <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 <br /> Test Result: ElPass 0Fail El Pass OFail 0Pass E]Fail 0Pass OFail <br /> Was sensor removed for testing'? (DYes []No [_]NA [3Yes E]No E]NA 0Yc-,s []No []NA E]Yes E]No E]NA <br /> Was sensor properly replaced and ElYes E]No E]NA []Yes E]No []NA E]Yes []No [—INA []Yes []No MNA <br /> verified functional after testin ? <br /> Not Tested Repairs Repairs MadeM.d. Not Tested Repairs Made L] Not Tested L]Repairs Made L] Not Tested Made <br /> Comments—anclude nilbrination on repairs nimleprior to testing, aiidrcc,,oninieticted,lbllovv-ul),tbl..fiiilcdtests) <br /> u <br />