Laserfiche WebLink
Page 3 of 6 <br />0 of <br />1. Please update your scope of work provided with your permit application, "Exhibit A", which needs to reflect <br />your proposed work (detailed in several email correspondences). <br />2. Provide a basic sketch showing which below ground pipes will be removed as part of this permit <br />3. Page 4 of permit application- please provide information for the rinsate hauler (item 5e) <br />4. Provide approval from the penetration manufacturer for penetration abandonment method and for using the <br />proposed schedule 80 pipe inside the existing penetration, and painting it with non -corrosive material. Will <br />the outside of this pipe (outside the sump) and inside portion of the pipe maintain its corrosion protection <br />for the duration (especially during/post routine SB989)? Alternatively consider using non -corrosive material <br />for this abandonment process. <br />Please don't hesitate to call me I you have any questions. <br />Elena K. Manzo, REHS <br />San Joaquin County <br />Environmental Health Department <br />1868 E. Hazelton Ave. <br />Stockton, CA 95205-6232 <br />Voice: (209) 953-7699 <br />From: mark crisp [mai Ito: marka-pc-inc.net <br />] <br />Sent: Friday, June 12, 2015 9:16 AM <br />To: Elena K. Manzo [EH] <br />Cc: Garrett Backus [EH] <br />Subject: Re: 430 W Center Street, Manteca, CA, <br />Elena, Please find attached the revised application, revised drawings and the ICC certs. The "existing <br />above ground raceway penetration pictures are attached as well. There is not a product number on them <br />but they are piping transition boots that are water tight. Please review and let me know if anything else is <br />required <br />Thank You, <br />Mark Crisp <br />P.C. Inc. <br />O: 800-359-2747 <br />C: 805-441-1963 <br />From: Elena K. Manzo [EH] <emanzoasicehd.com> <br />To: 'mark crisp' <markC@pc-inc.net> <br />Cc: Garrett Backus [EH] <gbackus@sacehd.com> <br />Sent: Wednesday, May 20, 2015 4:43 PM <br />Subject: RE: 430 W Center Street, Manteca, CA, <br />Dear Mark, <br />I am still in the process of reviewing your response and I may have further questions, but <br />meanwhile, to speed up the process, please provide the following information: <br />1) Fill out and provide the requested/missing permit application pages, please <br />refer to my letter dated May 8, 2015. <br />2) Revise your scope of work to reflect all the proposed work (including the <br />proposed pipe removal and penetration abandonment procedure, including the type <br />of "non corrosive material" you are going to apply to the schedule 80 pipe"). Also, <br />please provide a statement from the manufacturer of existing tank top sump <br />penetration(s) (this pertains to the flex line that will be removed) that the proposed <br />"plugging" method is approved with their penetration product. Provide a site map that <br />7/6/2015 <br />