Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department AUG 2 do 2017 <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siqov.onq/9hd <br /> ' " <br /> -!- <br /> Undergnd StoragkPrograrq4p � "Rit DEPART T" 1p -ALTH <br /> Facility Name: Facility Address: Date: <br /> Frontier California Inc.: Manteca CO 430 W Center St, Manteca August 03, 2017 <br /> UST System sevatlons.1r11 <br /> 2 <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status c V o R o Cos <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R o COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V o R Ei COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V u R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ci V c R ii COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V o R Ei COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V o R o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements ri V ri R Ei COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ci V ii R o COS <br /> Single Walled Non-Pressurize Piping <br /> 119 <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V o R o COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V o R Ei COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) 11 V [i R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) Ei V o R c COS <br /> OtherViolations <br /> 2010 See below Unlisted Administration/Documentation violation ri V o R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation o V o R o COS <br /> 2060 See below Unlisted Design/Construction violation c V ci R o COS <br /> 'SUMMARY 0117VIOLATIONS <br /> (c CLASS 11,or MINOR , oti <br /> ce to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved LIST monitoring plan. <br /> The monitoring plan for Tank 001 is not current and not approved by the EHD. Under"THE MONITORING IS <br /> PERFORMED USING THE FOLLOWING METHOD(S)", "TANK INTEGRITY TESTING"needs to be changed from <br /> "yes"to"no." The corresponding answer for"TANK INTEGRITY TESTING FREQUENCY"also needs to be <br /> changed accordingly. The monitoring plan must be uploaded to the California Environmental Reporting System <br /> (CERS). Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> FA0003838 PR0231425 SCO01 08/0312017 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 5 Underground Storage Tank Program OIR <br />