My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:36:41 PM
Creation date
6/23/2020 6:47:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AdIlk <br /> San Joaquin County Now <br /> AUG v 92017 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue,Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.smgov.org/e " Vt� �r1r=i'A TlL H 7ALT <br /> Under` r W'd Stora e;7 ro ram to We <br /> Facility <br /> Re ort,; <br /> 9 <br /> : <br /> Facility Name: Facility Address: Date: <br /> Frontier California Inc.: Manteca CO 430 W Center St, Manteca August 03,2017 <br /> SUM Y OF VIOLATIONS, <br /> ., <br /> v (CLASS I,GLASS II or MINOR-Notrce(4 Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> The facility failed to document daily alarms from the Veeder Root panel and failed to check that they were <br /> responded to appropriately.The missing alarms include 2 liquid warning alarms on 11/20/2016 and 12/12/2016 for <br /> the H4 piping vault sensor. Ensure that this facility documents all daily alarms from the Veeder Root panel and <br /> responds to each alarm appropriately. <br /> Monitoring records include: (1)date and time of all monitoring or sampling; (2)monitoring equipment calibration <br /> and maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in <br /> the field; (5)logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test <br /> results; (6) results of inventory readings and reconciliations. <br /> Send in information to EHD describing how the alarms were responded to. <br /> This is a minor violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the 12/20/2016 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include 2 liquid warning alarms on 11/20/2016 and 12/12/2016 for the H4 piping vault sensor. The <br /> H4(piping vault sensor)and H5(fuel polisher sensor)were not printed onto the 12/20/2017 designated operator <br /> inspection report. <br /> During the monthly inspection,the designated operator shall review the alarm history for the previous month, <br /> check that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> The designated operator on site printed out the alarms and addressed them on the designated operator monthly <br /> inspection report. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 214 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept. <br /> A log of monthly checks of the unburied single walled piping was not found on site. According to the designated <br /> operator(DO)on site, a company comes out to inspect the generator. The DO did not have the documents. For an <br /> emergency generator tank system,the unburied piping is exempt from regulation if visual inspections are made <br /> each time the system is operated, but no less than monthly, and a log is maintained. Immediately submit the <br /> inspection log to the EHD. <br /> This is a minor violation. <br /> FA0003838 PR0231425 SCO01 08/03/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.