My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 1:51:00 PM
Creation date
6/23/2020 6:47:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
YOSEMITE PETROLEUM
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231426_2072 W YOSEMITE_2000-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
402
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J. 4, <br /> �` <br /> SWRCB January 2002 Page- <br /> _,o of <br /> 6.. PIPINGSUMFTESTING <br /> Test Method Developed By: X Sump Manufacturer X Industry Standard Professional Engineer <br /> Other(Specify) <br /> Test Method Used: Pressure Vacuum X Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used:Incon Equipment Resolution: <br /> Sump#S r�"d Sump#42 Sump# Sump# <br /> Sump Diameter. <br /> Sump Depth: I V2 ;2 4 <br /> Sump Material: F 6 ` $ P t bee4/ S <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: 1 `� ;z`` <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: t <br /> Condition of sump prior to testing: DiA tY% ®t�� <br /> Portion of Sump Tested' <br /> Does turbine shut down when <br /> sump sensor detects liquid(both Yes No NA No NA Yes No NA Yes No NA <br /> product and water)?` <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe es No NA Yes No NA Yes No NA Yes No NA <br /> shutdown? <br /> Was fail-safe verified to be Yes o NA Yeso No NA Yes No NA Yes No NA <br /> operational?" <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15' <br /> yrr i /5 It�i✓. <br /> test: i a/72-),g <br /> Test Start Time: . 1 O; 142:441A" <br /> Initial Reading 419 <br /> Test End Time: .11 ,91 4 M 11 :0 <br /> Final Reading(RF): g <br /> Test.Duration: 15 rh i 15 YWAI <br /> Change in Reading(RF-&): -t, DU/s ppc� <br /> Pass/Fail Threshold or Criteria: +/-.002 +/-.002 +/-.002 +/-.002 <br /> Te <br /> Rasw ]fail,, Pass Fall", <br /> Was sensor removed for testing? es No NA No NA Yes No NA Yes No NA <br /> Was sensor properly replaced and <br /> verified functional after testing? es No NA No NA Yes No NA Yes No NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.