My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2006-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2024 11:04:03 AM
Creation date
6/23/2020 6:48:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2011
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2006-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT PIPING SUMP TESTING <br />Test Method By: o Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: o Pressure o Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descri tion Tank #1 Tank #2 <br />Tank product <br />Gasoline - 87 <br />Gasoline - 91 <br />Sump material <br />FRP <br />FRP <br />Sump diameter (inches) <br />48 <br />48 <br />Sump depth (inches) <br />53 <br />56 <br />Height from tank top to highest <br />piping penetration (inches) <br />21 <br />22 <br />Height from tank top to lowest <br />electrical penetration (inches) <br />17 <br />18 <br />Method of sump attachment to tank <br />Unknown <br />Unknown <br />Condition of sump prior to testing <br />Dry <br />Dry <br />Portion of sump tested <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Unknown <br />Unknown <br />Was fail-safe verified to be operational? <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Depth of water level from tank top (inches) <br />24 <br />25 <br />Wait time for water level to stabilize (hr:min) <br />0:10 <br />0:10 <br />Test start time <br />10:47 AM <br />9:51 AM <br />Initial Probe Reading <br />4.9811 <br />6.3208 <br />Test end time <br />11:02 AM <br />10:06 AM <br />Final Probe Reading <br />4.9799 <br />6.3204 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0012 <br />-0.0004 <br />Pass/Fail threshold (10.0020 inches / 14 Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS55 <br />Comments: <br />Depth of water level from tank top (inches) <br />24 <br />25 <br />Wait time for water level to stabilize (hr:min) <br />0:10 <br />0:10 <br />Test start time <br />10:47 AM <br />9:51 AM <br />Initial Probe Reading <br />4.9811 <br />6.3208 <br />Test end time <br />11:02 AM <br />10:06 AM <br />Final Probe Reading <br />4.9799 <br />6.3204 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0012 <br />-0.0004 <br />Pass/Fail threshold (10.0020 inches / 14 Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS55 <br />2006 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.