My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 12:06:22 PM
Creation date
6/23/2020 6:49:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: ❑UDC Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> UDC# 1-2 UDC#3-4 UDC# UDC# <br /> 7Height <br /> acturer: <br /> OF <br /> al: FIBERGLASS FIBERGLASS <br /> 10, 10" <br /> UDC Bottom to Top N/A N/A <br /> i in Penetration: <br /> UDC Bottom to N/A N/A <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to GOOD GOOD <br /> testing: <br /> Portion of UDC Tested' ALL ALL <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both X Yes ❑No NA X Yes ❑No NA YES ❑No NA Yes ❑No NA <br /> product and water)?* <br /> Turbine shutdown response time AUTOMATIC AUTOMATIC <br /> Is system programmed for fail- X Yes❑No ❑NA X Yes ❑No ❑NA Yes ❑No ❑NA Yes ❑No ❑NA <br /> safe shutdown?' <br /> Was fail-safe verified to be <br /> op erational?* IXYes D No ❑NA X Yes ❑No ❑NA Yes ElNo L1NA Yes ❑No ❑NA <br /> Wait time between applying 15 MINUTES 15 MINUTES <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 1:12 P.M. 1:12 P.M. <br /> Initial Reading Ri : 0.6392 0.2154 <br /> Test End Time: 1:27 P.M. 1:27 P.M. <br /> Final Reading(RF): 0.6391 0.2158 <br /> Test Duration: 15 MINUTES 15 MINUTES <br /> Change in Reading(RF-R,): 0.0001 0.0004 <br /> Pass/Fail Threshold or Criteria: .002 .002 <br /> Vass CI FaIiT... t __ii ass'; C ]F'ai 1 .. ..... Vass. .,D 7E aa1.:_..: Pass..f_p>t?at1 <br /> Was sensor removed for testing? X Yes ❑No NA : X Yes ❑No X NA ❑Yes ❑No NA ❑Yes ❑No NA <br /> Was sensor properly replaced and X Yes ❑No NA X Yes ❑No X NA ❑Yes ❑No NA ❑Yes ❑No NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testin , and recommended follow-up for failed tests) <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to aM of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.