COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 12:06:22 PM
Creation date
6/23/2020 6:49:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: D Pressure D Vacuum X Hydrostatic <br /> D Other(Spec6) <br /> Test Equipment Used: Equipment Resolution: .002 <br /> Sump#91 Sump#87 Sump#DIESEL Sump# <br /> 7SumpDiameter: 37" 37" 37"58" 58" 58: FIBERGLASS FIBERGLASS FIBERGLASS <br /> Height from Tank Top to Top of 34" 34" 34" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 28" 28" 28" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: GOOD GOOD GOOD <br /> Portion of Sump Tested' 50% 50% 50% <br /> Does turbine shut down when <br /> sump sensor detects liquid(both X Yes D No D NA X Yes D No DNA X Yes ❑No ❑NA Yes ❑No ❑NA <br /> product and water)?* <br /> Turbine shutdown response time AUTOMATIC AUTOMATIC AUTOMATIC <br /> Is system programmed for fail-safe X Yes ❑No [INA X Yes ❑No DNA X Yes ❑No ❑NA Yes ❑No D NA <br /> shutdown?' <br /> Was fail-safe verified to be X Yes ❑No D NA X Yes D No DNA X Yes ❑No DNA Yes ❑No D NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 MINUTES 15 MINUTES 15 MINUTES <br /> test: <br /> Test Start Time: 1:34 P.M. 1:56 P.M. 2:36 P.M. <br /> Initial Reading(Ri): 3.5087 3.5092 3.5129 <br /> Test End Time: 1:49 P.M. 2:11 P.M. 2:51 P.M. <br /> Final Reading(RF): 3.5092 3.5093 3.5142 <br /> Test Duration: 15 MINUTES 15 MINUTES 15 MINUTES <br /> Change in Reading(RF-R.): 0.0005 0.0001 0.0013 <br /> Pass/Fail Threshold or Criteria: .002 .002 .002 <br /> Testealt ..Past Y❑Fail , _....:: . I'a F �1 Sass CJ9iI,.. . )"ass l F1 <br /> Was sensor removed for testing? X Yes ❑No D NA. X Yes D No D NA X Yes D No ❑NA Yes ❑No ❑NA <br /> Was sensor properly replaced and X Yes D No DNA X Yes D No DNA X Yes D No ❑NA Yes D No DNA <br /> verified functional after testin . <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk{*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.