Laserfiche WebLink
SWRCB, January 2002 Page of <br />6. PIPING SUMP TESTING <br />Test Method Developed By, 1) Sump Manufacturer 0 Industry Standard 0 Professional Engineer <br />0 Other (Specify) <br />Test Method Used: 0 Pressure D Vacuum X Hydrostatic <br />0 Other (Specify) <br />Test Equipment Used, I Equipment Resolution. .002 <br />JUN 12 2014 <br />I If the entire depth of the sump is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is "NU' or "NA", the entire sump must be tested. (See SWRCS LG -160) <br />sump t 87 <br />Sump# 91 <br />Sump # DIESEL <br />Sump # <br />Sump Diameter: <br />42" <br />42" <br />42" <br />SumpDepth: <br />52" <br />54" <br />551, <br />Sump Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />Height from Tank Top to Top of <br />19" <br />16" <br />161, <br />Highest Piping Penetration; <br />Height from Tank Top to Lowest <br />5" <br />77P <br />7" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />GOOD <br />GOOD <br />GOOD <br />Portion of Sump Tested' <br />45% <br />45% <br />45% <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />X Yes ONo DNA <br />XYes QNo DNA <br />XYes ONo UNA <br />DYes ONo DNA <br />product and water)?" <br />�7 <br />Turbine shutdown response time <br />AUTOMATIC <br />AUTOMATIC <br />AUTOMATIC <br />Is system programmed for fail-safe <br />XYes oNo DNA <br />XYes DNo DNA <br />X Yes 0 No o NA <br />0 Yes 0 No 0 NA <br />shutdown? <br />Was fail-safe verified to be <br />XYes ONo, DNA <br />XYes. DNo [INA <br />X Yes 0 No 0 NA <br />0 Yes 0 No DNA <br />operational?" <br />Wait time between applying <br />pressure/vacuum/water and starting <br />15 MINUTES <br />15 MINUTES <br />15 MINUTES <br />test: <br />Test Start Time, <br />10:46AM 11:04AM <br />11:04AM 11:20AM <br />10.46AM 11:04AM <br />Initial Reading (RI): <br />6.212 6.214 <br />6.976 6.977 <br />6-313 6.313 <br />Test End Time: <br />11:01AM 11:19AM <br />11:19AM 11.-35AM <br />11.02AM 11:19AM <br />Final Reading <br />6.214 6,214 <br />6.977 6.976 <br />6.313 6.313 <br />Test Duration: <br />is MINUTES <br />15 MINUTES <br />15 MINUTES <br />Change in Reading (RF -R,): <br />.002 0 <br />.001 .001 <br />0 0 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />-M <br />19X I <br />111 <br />W, <br />Was sensor removed for testing? <br />X Yes 0 No 0 NA <br />X Yes ONO DNA <br />X Yes 0 No DNA <br />0 Yes 0 No 0 NA <br />Was sensor properly replaced and <br />X Yes 0 No DNA <br />X Yes 0No DNA <br />X Yes UNo DNA <br />0 Yes 13 No 12 NA <br />verified functional after testing? <br />I <br />I I <br />JUN 12 2014 <br />I If the entire depth of the sump is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is "NU' or "NA", the entire sump must be tested. (See SWRCS LG -160) <br />