My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_1985-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 2:12:37 PM
Creation date
6/23/2020 6:49:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2007
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_1985-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
401
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br />9� ain ill <br />6rii[kc atiB i Fac; <br />Page 2 <br />4. TANK ANNULAR TESTING <br />Is Tank Exempt From Testing?' <br />❑ Yes X No <br />l Yes ❑ No <br />❑ Yes No <br />Yes No <br />Tank Capacity: <br />553 gallons <br />Tank Material: <br />Fiberglass <br />Tank Manufacturer: <br />Owens-Corning <br />Product Stored: <br />Diesel <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 min. <br />Test Start Time: <br />10:30 am <br />Initial Reading (RI): <br />6.5" of VA <br />Test End Time: <br />11:30 am <br />Final Reading (RF): <br />6.5" of VA <br />Test Duration: <br />I hour <br />Change in Reading (RF -RI): <br />none <br />Pass/Fail Threshold or Criteria: <br />One hour, no loss <br />Test Result: <br />X Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ' ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ` No ❑ NA <br />❑ Yes EE No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? 11 <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes -]No ❑ NA <br />1 <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (California Code of Regulations, Title 23, Section 2637(a)(6)1 <br />I:\apps\JOBS\2007\S01289.KINGCA\SB989 KINGCA.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.