My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_1985-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 2:12:37 PM
Creation date
6/23/2020 6:49:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2007
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_1985-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
401
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ 111 101161111,I IWINOR"I "i <br />Page 4 <br />Facility is Not Equipped With Fill Riser Containment Sumps . <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />Test Method Developed By: <br />❑ Sump Manufacturer <br />❑ Other (Spec) <br />X Industry Standard ❑ Professional Engineer <br />Test Method Used: <br />Pressure <br />-' Other (Spec) <br />❑ Vacuum <br />X Hydrostatic <br />Test Equipment Used: Ronan/Caldwell Hydrostatic Sump Tester <br />OEM <br />Diesel Vent Transition <br />Equipment Resolution: 0.0000" <br />Piping Transition <br />Sump Diameter: <br />46" <br />28" x 25" <br />29" x 20" <br />Sump Depth: <br />60 `/2 " <br />30" <br />30" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />14" <br />7" <br />9" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />17" <br />16" <br />18" <br />Condition of sump prior to <br />testing: <br />Clean <br />Clean <br />Clean <br />Portion of Sump Tested <br />-20" <br />-18" <br />-18" <br />Sump Material: <br />FG <br />FG <br />FG <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 min <br />10 min <br />10 min <br />Test Start Time: <br />12:30 prn <br />11:15 am <br />1:00 pm <br />Initial Reading Rj): <br />Test End Time: <br />1:00 prn <br />11:45 am <br />1:30 pm <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -RI): <br />Pass/Fail Threshold or Criteria: <br />PASS <br />= No Loss or Loss of 0.0020" or less in 30minutes <br />Test Result: <br />X Pass ❑ Fail <br />X Pass ❑`Fail <br />X Pass - ❑ Fail <br />0 Pass 0 Fail <br />Is there a sensor in the sump? <br />X Yes ❑ No <br />XYes ❑ No <br />X Yes iC] No <br />❑ Yes <br />_.� No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />XYes _ ❑No ❑NA <br />XYes --No❑NA <br />XYes ENO _NA <br />❑Yes ❑No <br />ENA <br />Was sensor removed for testing? <br />XYes ❑No ENA <br />XYes ❑INo ❑NA <br />XYes CNo -_NA <br />[Yes LNo <br />❑NA <br />Was sensor properly replaced and <br />functional after testing? <br />, _NoNA <br />XYes ',-No-NA <br />XYes E No -Z <br />C✓Yes -- No <br />-_NAverified <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Note: Caldwell Sump Tester used for hydrostatic test of all sumps. <br />Vent and Pipe Transition Sumps electrical penetrates from the top of the box and 90's into an electrical box in the transition sumps. <br />I:\apps\JOBS\2007\S01289.KINGCA\SB989 KINGCA.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.