My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1993-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
25651
>
2300 - Underground Storage Tank Program
>
PR0231628
>
COMPLIANCE INFO_1993-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
6/23/2020 6:50:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1993-1998
RECORD_ID
PR0231628
PE
2361
FACILITY_ID
FA0003835
FACILITY_NAME
SMK CHEVRON
STREET_NUMBER
25651
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00514120
CURRENT_STATUS
01
SITE_LOCATION
25651 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231628_25651 N HWY 99_1993-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />L Re -*s ofStandard EADation <br />Automatic Tank Gauging System (ATGJ <br />This form tells whether the automatic tank gauging system (ATGS) described below <br />complies with the performance requirements of the federal underground storage tank <br />regulation. The evaluation was conducted by the equipment manufacturer or a consultant <br />to the consultant to the manufacturer according to the U.S. EPA's "Standard Test <br />Procedure for Evaluating Leak Detection Methods: Automatic Tank Gauging Systems." <br />The full evaluation report also includes a form describing the method and a form <br />summarizing the test data. <br />Tank owners using this leak detection system should keep this form on file to prove <br />compliance with the federal regulations. Tank owners should check with State and local <br />agencies to make sure this form satisfies their requirements. <br />ATGS Description <br />Name CEI 3000 Tank Level Module (0.1 aDh: Normal Test Mode) <br />Version Number TLP2 <br />Vendor Control Enginem, Inc. <br />107 Menard Road <br />(street address) <br />Houma LA 70361 (504) 872-4541 <br />(city) (state) (zip) (phone) <br />Evaluation Results <br />This ATGS, which declares a tank to be leaking when the measured leak rateexceedsthe <br />threshold of 0.05 gallon per hour, has a probability of false alarms [P(FA)l of 0.9 <br />The corresponding probability of detection [P(D)l of a 0.1 gallon per hour leak is 99.1 <br />The minimum water level (threshold) in the tank that the ATGS can detect is 0.49 <br />inches. <br />The minimum change in water level that can be detected by the ATGS is 0.05 inches <br />(provided that the water level is above the threshold).. <br />Therefore, this ATGS 0 does 11 does not meet the federal performance standards <br />established by the U.S. Environmental P—rotectioja Agency (0.2 gallon per hour at P(D) of <br />95% and P(FA) of 5%), and this ATGS Q9 does U does not meet the federal performance <br />standard of measuring water in the bottom of the tank to the nearest 1/8 inch. <br />Test Conditions During Evaluation <br />The evaluation testing was conducted in a 10.000 gallon 0 steel 1:1 fiberglass tank that <br />was 96 inches in diameter and _3_24 inches long. <br />the temperature difference between product added to fill the tank and product already in <br />the tank ranged from -5.4 F to 7.4 *F, with a standard deviation of _4.3 OF. <br />The tests were conducted with the tank product levels _50 and _2L% full. <br />The product used in the evaluation was No. 2, Diesel . <br />ATGS - Results Forms <br />Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.