COMPLIANCE INFO_1993-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
25651
>
2300 - Underground Storage Tank Program
>
PR0231628
>
COMPLIANCE INFO_1993-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
6/23/2020 6:50:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1993-1998
RECORD_ID
PR0231628
PE
2361
FACILITY_ID
FA0003835
FACILITY_NAME
SMK CHEVRON
STREET_NUMBER
25651
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00514120
CURRENT_STATUS
01
SITE_LOCATION
25651 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231628_25651 N HWY 99_1993-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LJ Floults of Standard *aluation <br />VolumetricTightness Testing i • <br />This form tells whether the tank tightness testing method described below complies with <br />the performance requirements of the federal underground storage tank regulation. The <br />evaluation was conducted by the equipment manufacturer or a consultant to the <br />consultant to the manufacturer according to the U.S. EPA's "Standard Test Procedure for <br />Evaluating Leak Detection Methods: Volumetric Tank Tightness Testing Methods." The <br />full evaluation report also includes a form describing the method and a form summarizing <br />the test data. <br />Tank owners using this leak detection system should keep this form on file to prove <br />compliance with the federal regulations. Tank owners should check with State and local <br />agencies to make sure this form satisfies their requirements. <br />Methoa Description <br />Name CEI 3000 Tank Level Module (TTT Normal Test Mode) <br />Version Number TLP2 <br />Vendor Control Engineers, Inc <br />107 Menard Road <br />street address) <br />Houma LA 70361 504 872-4541 <br />city state zap (phone) <br />This method, which declares a tank to be leaking when the measured leak rate exceeds <br />the threshold of 0.05 gallon per hour, has a probability of false alarms [P(FA)] of 08 %. <br />The corresponding probability of detection [P(D)] of a 0.1 gallon per hour leak is 99.2%. <br />Therefore, this method ® does ® does not meet the federal performance standards <br />established by the U.S. Environmental Protection Agency (0.10 gallon per hour at P(D) <br />of 95% and P(FA) of 5%). <br />Test Conaitions During Evaluation <br />The evaluation testing was conducted in a 10 000 gallon ® steel D fiberglass tank that <br />was 96 inches in diameter and 324 inches—Tong. <br />The tests were conducted with the tank 95 percent full. <br />The temperature difference between product added to fill the tank and product already <br />in the tank ranged from -6.4 OF to 7.4 OF, with a standard deviation of 4.3 OF. <br />The product used in the evaluation was No. 2, Diesel . <br />Volumetric TTT Method - Results Form Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.