My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-1999
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_1995-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 3:55:50 PM
Creation date
6/23/2020 6:51:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-1999
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_1995-1999.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUA NK/LINE/LEAK DETECTOR T§G REPORT <br /> TANKNOLOGY-NDE <br /> TEST DATE: 03/18/98 WORK ORDER NUMBER: 2203916 <br /> CLIENT: SHELL OIL COMPANY SITE: SHELL 204-4416-0806 <br /> Tank ID: 1 Material:Dw FISERG Bottom to top fill in inches: 181.5 <br /> Product:PREMIUM Tank manifolded:No Bottom to grade fill in inches: 190.0 <br /> Capacity in gallons: 14,976 Vent manifolded:No Fill pipe length in inches: 67.5 <br /> Diameter in inches: 114.00 Vapor recovery manifolded:YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 323 Impact Valves Operational: Stage I vapor recovery: DUAL <br /> Tank age(years): Overfill protection: YES Stage II vapor recovery: ASSIST <br /> Fuel pure rating: Overspill protection: YES Installed: ATG <br /> COMMENTS CP installed on: / / <br /> THIS TANK IS LISTED AS #1 ON THE MONITOR SYSTEM. <br /> tart in n m New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Water Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: Make: <br /> VEEDERROOT <br /> Probe Water Level: Model: L.L.D. <br /> Ingress Detected: Water Bubble Ullage S/N: TLS350-PLED <br /> Test time: Open time in sec: <br /> VacuTect Test Type: Holding psi: 19 <br /> VacuTect Probe Entry Point: Resiliancy cc: 85 <br /> Pressure Set Point: Test leak rate ml/m: 189.0 <br /> Tank water level in inches: Metering psi: 10 <br /> Water table depth in inches: Calib.leak in gph: 3.00 <br /> Determined by(method): Results: PASS <br /> Result: <br /> COMMENTS COMMENTS <br /> Iloilo= <br /> Material: DW FISERG <br /> Diameter(in): 2.0 <br /> Length(ft): 100.0 <br /> Test psi: <br /> Bleedback cc: <br /> Test time(min): <br /> Test 1:Start time: <br /> Finish psi: <br /> Vol change cc: <br /> Test 2:Start time: <br /> Finish psi: <br /> Vol change cc: <br /> Test 3:Start time: <br /> Finish psi: <br /> Vol change cc: <br /> Final gph: <br /> Result: <br /> Pump type: PRESSURE <br /> COMMENTS Pump make: FE PETRO <br /> 8900 SHOAL CREEK,BUILDING 200,AUSTIN,TEXAS 78757(512)451-6334 Printed 03/20/98 10:17 MSHAW <br />
The URL can be used to link to this page
Your browser does not support the video tag.