My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-1999
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_1995-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 3:55:50 PM
Creation date
6/23/2020 6:51:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-1999
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_1995-1999.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VEEDER-ROOT PRESSURIZED LINE LEAK DETECTION <br /> SITE PREPARATION ANDHr <br /> INSTALLATION INSTRUCTIONS <br /> SECTION 1. INTRODUCTION PLLD executes these tests automatically,there is no need <br /> for separate annual line leak testing. <br /> A. GENERAL There are three versions of the PLLD System available, <br /> This manual describes installation procedures for the depending on the brand of pump and the PLLD valve <br /> Veeder-Root Pressurized Line Leak Detection (PLLD) hype chosen: <br /> System, Form No. 848490-001, -002, or-003. This sys- <br /> tem is intended for use in FE Petrol'' and Red Jacket- PLLD System <br /> Pumps used with a TLS-350"m UST Monitoring System Pump Brand Valve Type Form No. <br /> or a TLS-350RI Environmental & Inventory Manage- <br /> ment System. FE Petro None* 848490-001 <br /> B. DAMAGE CLAIMS Red Jacket In-line check valve 848490-002 <br /> and Tokheim <br /> Thoroughly examine all components as soon as received. Red Jacket SwiftCheck-rm 848490-003 <br /> "•, NOTE: Insist that the carrier's agent verify the and Tokheim valve(optional) <br /> ° inspection and sign the description. *Requires that a Precision Check Valve (FE Petro <br /> Immediately notify the delivering carrier of damage or Part Number 400153925) be installed. <br /> loss, either in person or by telephone. Mail written con- <br /> firmation within 48 hours. Railroads and motor carriers 1. FE Petro Submersible Pump <br /> are reluctant to make adjustments for damaged merchan- <br /> dise unless inspected and reported promptly. The PLLD System for use with FE Petro submersible <br /> Risk of loss, or damage to merchandise remains with the pumps(Form No. 848490-001)contains these items: <br /> buyer. It is the buyer's responsibility to file a claim with • 1 -Line Leak Sensor, Part No. 330377-001 <br /> the carrier involved. • 6-WARNING Tags,Part No. 329801-001 <br /> Immediately advise your Veeder-Root representative, Epoxy Packs, Wire Nuts and Watertight Cord Grip <br /> distributor, or the factory so that we may assist you. 1 - Site Preparation and Installation Manual <br /> t <br /> C. RETURN SHIPPING I I b-A NOTE: See System Requirements, SECTION 1. <br /> D., Step 2. <br /> All return shipments of Veeder-Root products must be <br /> prepaid. If the product is damaged, return it in the origi- 2. Red Jacket and Tokheim Pumps using PLLD In- <br /> nal shipping container.Veeder-Root will accept no liabil- line Check Valve <br /> ity for damage caused by improper packing. Address the The PLLD System with in-line check valve for use with <br /> shipment to Veeder-Root Co., 6th Avenue at Burns Red Jacket and Tokheim pumps (Form No. 848490-002) <br /> Crossing,Altoona, Pennsylvania 16602. contains these items: <br /> D. SYSTEM REQUIREMENTS 1 -Line Leak Sensor, Part Number 330377-001 <br /> • 1 -In-Line Check Valve,Part Number 330368-001 <br /> 1. Be sure the Veeder-Root TLS-350 or TLS-35OR Sys- . 1 -Pump Port Strainer, Part Number 329861-001 <br /> tem has PLLD Interface and PLLD Controller Mod- . 6-WARNING Tags,Part Number 329801-001 <br /> ules installed. If these modules are not installed, the . Epoxy Packs, Wire Nuts and Watertight Cord Grip <br /> TLS system will not be able to accept inputs from the 0 1 - Site Preparation and Installation Manual <br /> PLLD system. <br /> 2. If you are installing the PLLD System into a FE 3. Red Jacket and Tokheim Pumps using PLLD <br /> Petro'"' Pump, be sure it contains a Precision Check SwiftCheck"m Valve <br /> Valve (FE Petro Part No. 400153925)before begin- The PLLD System with the SwiftCheck- valve option <br /> ning installation. The PLLD system will not work if for use with Red Jacket and Tokheim pumps (Form No. <br /> the Precision Check Valve is not in place. 848490-003)contains these items: <br /> • 1 -Line Leak Sensor,Part Number 330377-001 <br /> E. SYSTEM DESCRIPTION • 1 -SwiftCheck"A Valve,Part Number 330379-001 <br /> The PLLD System performs 3.0 gph leak tests following - 6-WARNING Tags,Part Number 329801-001 <br /> each dispense. The PLLD System allows line tests at full • Epoxy Packs, Wire Nuts and Watertight Cord Grip <br /> pump pressure for highly accurate 0.1 gph tests. Since - 1 - Site Preparation and Installation Manual <br /> 1 <br /> L <br />
The URL can be used to link to this page
Your browser does not support the video tag.