My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2000-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 3:59:11 PM
Creation date
6/23/2020 6:51:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2003
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_2000-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
479
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
u <br />leg of the 45° containment elbow and the side outlet run <br />of the containment tee. <br />Refer to Table 2.3.1 for the maximum length that can be <br />removed and for the minimum nipple length of both <br />product piping and secondary containment piping. <br />To prevent interference of the pipelines, do not locate two <br />containment fittings closer than shown in Table 2.3.2, Fig. <br />2.3.1. <br />the Storage Tank <br />SECTION 4 Pkermination Connections <br />2.4.2 Termination at the Dispenser <br />Termination of the secondary containment piping system <br />at the dispenser is accomplished using a termination fit- <br />ting with or without the %" NPT threaded outlet (see Fig. <br />2.4.2). To facilitate ease of terminating, special bell x male <br />adapters or special sleeve couplings for secondary contain- <br />ment are available for use with secondary containment <br />termination fittings. The special adapters and sleeve cou- <br />plings have been machined on the O.D. to fit the sec- <br />ondary containment termination fittings. If machined <br />bell x male adapters are not available, standard male <br />threaded adapters or sleeve couplings may be used (see <br />Table 2.4.1). Non -machined surfaces must be sanded to fit <br />the secondary containment fittings (see Fig. 2.4.3). <br />"n of the secondary containment piping system <br />" forage tank is accomplished using a termination 2.4.3 Termination Fittings (See Table 2.4.1) <br />R <br />ding with %" female NPT threaded outlet (see Fig. 2.4.1). <br />The X" threaded outlet allows easy access for pressure test- <br />ing of the secondary containment piping system, and may <br />also be used as an access for a leak detection probe. <br />Impact Valve <br />Fiberglass <br />6h, <br />!Flexible <br />nnector <br />FIGURE 2.4.2 <br />Scarf O.D. of pipe so that the <br />fitting halves fit together <br />when assembled by hand. <br />If there is a gap between the fitting <br />halves when assembled by hand, <br />pipe must be scarfed more. <br />FIGURE 2.4.3 <br />Note: Termination fittings will not work with bell x female threaded <br />adapters. <br />rings 10 25 <br />
The URL can be used to link to this page
Your browser does not support the video tag.