My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:40:14 PM
Creation date
6/23/2020 6:51:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
441
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 �` 'a,, • Environmental Health Department <br /> SAN3JOAQUIN § <br /> ._C 0 u v T Y...,... <br /> Unaer round.,Storage Tank Ped on g _ <br /> Facility Name: Facility Address: Date: <br /> Marks Fuel&Food, Inc. 880 E VICTOR RD, LODI November 08,2018 <br /> SUMMARY OF VIOLATIONS, <br /> (CLASS 1,CLASS II,or MINOR Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to document all the alarms from the attached alarm history on the designated <br /> operator monthly inspection report and failed to check that they were responded to appropriately. The missing <br /> alarms include: <br /> -1-5-91 annular on 7/31/18. <br /> -L9-UDC 5/6 from 10/9/18 <br /> -L-11-UDC 10/7/18 <br /> Furthermore the designated operator failed to print out alarm L9 during the inspection report conducted on 7/6/18, <br /> 8/23/18 <br /> The designated operator marked"N/A"for"Are under dispenser containment areas free of water, debris,and <br /> hazardous substance?'and"Leak detection is properly located within under-dispense containment"during the <br /> 9/20/17, 10/20/17, 11/16/17, 2/21/18,and 4/27/18. <br /> -The designated operator failed to mark if"Are spill buckets(containment structures)free of water, debris, and <br /> hazardous substance?"for the 8/23/18. <br /> -The designated operator(DO)failed to include the CERS ID, the zip code of the site,failed to mark"is the <br /> containment sump free of damage,water, debris, and hazardous substance?"furthermore the DO failed to mark if <br /> "are all sensors in the under-dispenser containment located to detect a leak at the earliest opportunity?"in the <br /> 9/27/18 and 10/24/18 monthly inspection report. <br /> -The designated operator failed to check and note the correct test dates for the overfill prevention equipment <br /> inspection and secondary containment testing in the 9/27/18 and 10/24/18 inspection report. <br /> During the monthly inspection,the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 301 HSC 25292.1(a) UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> Fuel filters in UDC 1/2, 3/4,5/6,and 7/8 were observed outside of all under dispenser containments at the facility. <br /> The underground storage tank system shall be operated to prevent unauthorized releases. Immediately contact a <br /> properly licensed,trained, and certified contractor to replace or upgrade the component under permit and inspection <br /> with the EHD, if required. <br /> This is a Class II violation. <br /> 314 HSC 25290.1,25290.2,25291 Failed to have secondary containment or secondary containment not tight. <br /> The fuel filters in UDC 1/2,3/4, 5/6 and 7/8 are not contained within the secondary containment(under dispenser <br /> containment)for the dispenser piping.All primary portions of the UST system must be provided with adequate <br /> secondary containment. Immediately make all all necessary alterations to provide secondary containment or meet <br /> all applicable title 23 requirements for a UST system, under permit and inspection of EHD, if required. <br /> This is a repeat violation, Class Il. <br /> FA0003862 PR0231746 SCO01 11/08/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.