Page 4 of 9 <br />3. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: See attached testing procedures Equipment Resolution: <br />Sump # 87-1 <br />immm MEN= <br />Sump # 87-2 Sump # 91 <br />000M <br />Sump # <br />Sump Diameter: 48" <br />48" 48" <br />Turbine shutdown response time <br />Sump Depth: <br />55" <br />55" 53" <br />Is system programmed for fail-safe <br />shutdown?` <br />Sump Material & Manufacturer: <br />Fiberglass <br />Fiberglass Fiberglass <br />Was fail-safe verified to be <br />operational?" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />16" <br />16" 16" <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />18" <br />16" 16" <br />Test Start Time: <br />Condition of sump prior to testing: <br />Fair <br />Fair Fair <br />Initial Reading (R1): <br />POrtlOri Of Sum Tested' <br />Sump <br />Above highest <br />penetration <br />Above highest Above highest <br />penetration penetration <br />Above highest <br />penetration <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?" <br />❑ Yes ❑ No ® NA <br />❑Yes ❑ No ® NA ❑Yes ❑ No ® NA <br />❑ Yes ❑ NO ®NA <br />Turbine shutdown response time <br />N/A <br />N/A N/A <br />N/A <br />Is system programmed for fail-safe <br />shutdown?` <br />❑ Yes ❑ No ® NA <br />❑Yes ❑ No ®NA ❑Yes ❑ No ®NA <br />❑ Yes ❑ No ® NA <br />Was fail-safe verified to be <br />operational?" <br />❑ yes ❑ No ®NA <br />❑Yes ❑ No ®NA ❑Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />30 minutes <br />30 minutes 30 minutes <br />30 minutes <br />Test Start Time: <br />11:01am <br />11:01am 11:06am <br />Initial Reading (R1): <br />4.8129 <br />1.8298 0.8070 <br />Test End Time: <br />11:16am <br />11:16am 11:21am <br />Final Reading (RF): <br />4.8132 <br />1.8298 0.8059 <br />Test Duration: <br />15 min <br />15 min 15 min <br />15 min <br />Change in Reading (RF -R1): <br />0.00026 <br />0.00001 0.00119 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 0.002 <br />0.002 <br />Test Result: <br />Pass ❑ Fail <br />Z' Pass; ❑ Fail ED Pass ❑ Fail <br />❑ Pass <br />El Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA ®Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />® Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA ®Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to �Lny of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />