My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:39:37 PM
Creation date
6/23/2020 6:52:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
sw <br />f <br />0 <br />0 <br />UNIFIED PROGRANJ CONSOLIDATED FORNI <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN (Page 2of2) <br />VI. UNDER DISPENSER CONTAININIENT (UDC) MONITORING <br />1. UDC MO',JTORING IS PERFORMED USING THE FOLLOWING METHOD <br />490-346 <br />0 1. CONTINUOUS ELECTRONIC MONITORING [12, FLOAT AND CHAIN ASSEMBLY C3 3. ELECTRONIC STAND-ALONE <br />7— 4. NO DISPENSERS [:199. OTFER Specify): -------------------------------------------------------------------------------------------------------------------------- <br />----------- — ---- - ------------------------ <br />PANEL MANUFACTURER: . .............. 40-5' MODEL# <br />L <br />490-56. <br />........ . <br />1 - -------------------------- 4911-17 MODEL #(S): <br />LEAK SENSOR MANUFACTURER: <br />490-58 <br />DETECTION OF A LEAK INTO T HE UDC TRIGGERS AUDIBLE AND VISUAL ALARv[S a. YES ❑ b. NO <br />490-59 <br />UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN a. YES ❑ b. NO <br />490-60. <br />FAILURE / DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. a. YES ❑ b. NO <br />490-61 <br />UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. a. YES ❑ b. NO <br />490-61 <br />2. UDC CONSTRUCTION IS [ILSINGLE-WALLED r-12.DOUBLE-WALLED <br />------------ <br />490-63 <br />IF DOUBLE WALLED: <br />490-a a <br />L UDC INTERSTITIAL SPACE IS MONITORED BY: ---- [I 2. -PRESSURE El 3. -VACUUM --------- --- ------------------------------------------------ -------- <br />---- - <br />__E] -I -.-LIQUID <br />A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS Ela.YES Elb.NO <br />490-64b <br />VII. PERIODIC SYSTEM TESTING <br />M 1. ELD TESTING, THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED <br />490-65, <br />M MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36MONIHS AS REOUIREP__(3?_CCR_§2644 ------ 1) ........... <br />LEAK DETECTION (E4 ................. <br />2. SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. <br />---ANNUALLY. --- __--,- __ <br />490-66 <br />3.SPILL ---BUCKETS ---`----__--- A --- R_E_ ---TESTED <br />VIII. RECORDKEEPING <br />The following monitoring/maintenance records are kept for this facility: <br />90 Alarm logs 490-68a a Visual Inspection Records 490-68b El Tank integrity testing results 490-68c <br />El SIR testing results (and supporting documentation records). 490-68d ❑ Tank gauging results (and supporting documentation records). 490-68e <br />ATG Testing results (and supporting documentation records), 490-68f ❑ Corrosion Protection 60 -day Jogs 490-68g <br />❑ Equipment maintenance and calibration records. 490-68h <br />IX. TRAINING <br />Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to theirJob duties 490-69a <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) <br />THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) 490-69b <br />OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) 490-6% <br />F1 CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-69d <br />[I CALIFORNIA UNDERGROUND STORAGE TANK LAW 490-69t <br />El STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION" 490-69f <br />❑ SWRCB PUBLICATION. "UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" 490-699 <br />El OTHER (Specify): M69h, M69i <br />This facility has a "Designated UST Operator" who has passed the California UST System Operator Exam administered by the International Code Council <br />(ICC). <br />The "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems annually, and within 30 days of hire. <br />This <br />training will include, but is not limited to, the following: <br />> Operation of the UST systems in a manner consistent with the facility's best management practices <br />➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring'Plan <br />> The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br />> Names of contact person(s) for emergencies and monitoring alarms 490-70 <br />X. COMMENTS/ADDITIONAL INFORMATION <br />Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. 490-71 <br />XI. PERSONNEL RESPONSIBILITIES <br />The UST Owner/Operator is responsible for ensuring that: 1) the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered <br />by <br />this plan occurs, 2) all conditions that indicate a possible release are investigated, and 3) all monitoring records are maintained properly. <br />The following per n(s) are responsible for performing the monitoring and equipment i t <br />V) Cq 4'JC! <br />r��K <br />NAME ((:k' 490-72 TITLE fnL, I L ntj <br />490-73 <br />NAME f�j+�q,-L Gvp I Wvvvvt�( 490-74 TITLE 011y(JI:�-, se ,,fL <br />J4 <br />490.75 <br />The Designated Operator shiall- performi a nionthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operdtor <br />of any <br />conditions that need follow-up action. <br />XII. OWNER/OPERATOR SIGNATURE <br />CERTIFICA" I ce if e)nformation provided herein is true and accurate to the best of my knowledge. <br />APPLICANT490-76 <br />DATE: <br />490-77 <br />'r <br />REPRESENTING: 1. Tank /O-rator FacilityQwner/Operator Q 3( Authorized Representatwe of Owner <br />490-78 <br />490-79 <br />APP CANT NAME (Ppint), <br />APPLICANT, TITLE: <br />r <br />
The URL can be used to link to this page
Your browser does not support the video tag.