My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:39:37 PM
Creation date
6/23/2020 6:52:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 4 of 6 <br />6. PIPING SUMIP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer X Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: INCON TS -STS V2.1 Equipment Resolution: 0.0000" <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Sump #STP North <br />Sump #STP South <br />Sump Diameter: <br />42" <br />42" <br />Sump Depth: <br />52" <br />49" <br />Sump Material: <br />fiberglass <br />fiberglass <br />Height from Tank Top to Top of <br />14" <br />14" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />20" <br />19" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Clean <br />Clean <br />Portion of Sump Tested' <br />2" Above Highest <br />2" Above Highest <br />Piping Penetration <br />Piping Penetration <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />product and water)?* <br />Turbine shutdown response time <br />2 Seconds <br />2 Seconds <br />Is system programmed, for fail-safe <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />shutdown? <br />Was fail-safe verified to be <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />-operational?* <br />Wait time between applying <br />pressure/vacuum/water and starting <br />15 Minutes <br />15 Minutes <br />test: <br />Test Start Time: <br />8:44 / 9:00 <br />9:34 / 9:50 <br />Initial Reading (RO: <br />4.826 /4.825 <br />3.932 / 3.931 <br />Test End Time: <br />8:59 / 9:15 <br />9:49 / 10:05 <br />Final Reading (RF): <br />4.825 / 4.825 <br />3.931 / 3.931 <br />Test Duration: <br />15 min. each <br />15 min. each <br />Change in Reading (RF -RI): <br />.001/0 <br />.001/0 <br />Pass/Fail Threshold or Criteria: <br />0.0020" <br />0.0020" <br />Test Result: <br />X Pass 0 Fail <br />X Pass ' ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.