Laserfiche WebLink
F. In -Tank Gauging / SIR Equipment: <br />X❑ Check this box if tank gauging is used only for inventory control. <br />❑ Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />C om fete the <br />I011owm <br />checklist: <br />❑ Yes <br />F]No* <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />❑ Yes <br />❑ No* <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />❑ Yes <br />❑ No* <br />Was accuracy of system product level readings tested? <br />❑ Yes <br />❑ No* <br />Was accuracy of system water level readings tested? <br />❑ Yes <br />❑ No* <br />Is <br />Were all probes reinstalled properly?AIMM OVEB <br />❑ Yes <br />❑ No* <br />❑ Yes <br />❑ No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />G. Line Leak Detectors (LLD): ❑ Check this box if LLDs are not installed. <br />Complete the following checklist: <br />Yes <br />❑ No <br />For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance?(Check <br />❑ N/A <br />all that apply) Simulated leak rate: 0 3 g.p.h.; E10.1 g.p.h ; ❑ 0.2 g.p.h. <br />❑X Yes <br />❑ No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />0 Yes <br />❑ No* <br />Was the testing apparatus properly calibrated? <br />❑X Yes <br />❑ No* <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />❑ N/A <br />❑ Yes <br />❑ No* <br />For electronic LLDs, does the turbine automatically shut off i fthe LLD detects a leak? <br />❑X N/A <br />❑ Yes <br />❑ No* <br />For electronic LLDs, does the turbine automatically shut off ifany portion of the monitoring system is disabled or <br />❑%� N/A <br />disconnected? <br />❑ Yes <br />❑ No* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or <br />XJ N/A <br />tails a test? <br />❑ Yes <br />❑ No* <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />❑x N/A <br />0 Yes <br />❑ No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />* In the Section It below, describe how and when these deficiencies were or will be corrected. <br />H. Comments: <br />