My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2014-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2020 12:18:05 PM
Creation date
6/23/2020 6:53:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2018
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2014-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Unified Grocers Inc. <br />Facility Address: <br />1 1990 N PICCOLI RD STOCKTON <br />Date: <br />November 23 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />103 <br />HSC 25292.2 Current financial responsibility documents not submitted. <br />Financial responsibility documents have not been submitted to the EHD. A Certification of Financial Responsibility <br />was not submitted. The insurance documents submitted are expired. Current financial responsibility documents are <br />required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/, and upload the required documents. <br />This is a repeat violation, Class II. <br />104 <br />CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />The UST Tank Information form for the diesel tank is not current in CERS. The product piping is incorrectly listed as <br />plastic primary with FRP secondary; the product piping observed on site was double walled fiberglass in the 1.5 hp <br />turbine sump and steel in the 5 hp turbine sump. The vent lines are incorrectly listed as steel; the vent piping <br />observed on ste was single walled fiberglass. The under dispenser containment (UDC) was listed as steel; the UDC <br />observed on site was single walled plastic. Any change of information must be updated in CERS within 30 days of the <br />changes. Immediately log into CERS, update the required information, and submit for review by the EHD. <br />This is a Class II violation. <br />106 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The monitoring plan is not current and/or not approved by the EHD. The monitoring plan has the following issues: <br />- The annular sensor is listed as a Red Jacket FXIV; the annular sensor was observed to be a Veeder Root 420. <br />- The plan indicates that there are not sump sensors; the sump sensors were observed to be Veeder Root 205. <br />- The plan indicates that there is no positive shutdown during sensor out and power out; positive shutdown was verified <br />for both conditions during the inspection. <br />- The plan indicates that there are no UDCs; the UDC sensor was observed to be a Veeder Root 205. <br />- The plan indicates that there are no leak detectors; the leak detectors were observed to be a FE Petro STP -MLD -D <br />(1.5 hp) and a VMI 99LD3000 (5 hp) mechanical line leak detectors. <br />- The plan incorrectly indicates that alarm logs are not being maintained on site. <br />- No second person responsible is listed. <br />The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br />into CERS, make the necessary changes, and submit for review by the EHD. <br />This is a repeat violation, Class ll. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The map submitted does not include the locations of <br />sumps, sensors, dispensers, or the monitoring panel. A site plan must be submitted identifying the locations where <br />monitoring will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of a complete, accurate UST Monitoring Site Plan. <br />This is a minor violation. <br />Received by <br />Inspector: <br />Phone: <br />Date: <br />(initial): <br />STACY RIVERA, Senior REHS <br />(209) 468-3440 <br />11/23/2015 <br />Page 4 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.