My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2014-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2020 12:18:05 PM
Creation date
6/23/2020 6:53:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2018
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2014-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 RECEIVED <br />' Appendix VI <br />(Copies of Monitoring System Certification form and UST'MonkoringPlot Plan available athttp:G%www.waterboar s.2o1J <br />ca gov .) <br />MONITORING SYSTEM CERTIFICATION ENVIRONMENTAL <br />For Use By All Jurisdictions W'ith�r the State of California WI:Al T1 -t ncmAQTARr-klT <br />Authority Cited: Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 23, California Code ofRegulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who perforans the work. A copy of this form must be provided to the tank system owner/operator <br />owner/operator must submit a copy ofthis form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Unified Grocers, Inc Facility ID: 01 <br />Site Address: 1990 Piccoli Rd. <br />Facility Contact Person: Mike Young <br />Make/Model of Monitoring System: Veeder Root TLS -350 <br />City: Stockton Zip: 95215 <br />Contact Phone No.: 209-931-7416 <br />Date of Testing/Servicing: 2015-11-23 <br />The <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />-Tank 1. Die. �_.847390 109 Tank <br />Tank ID: _ ginglPro..... _....e.. ....._� _,® <br />I Tank ID <br />X Gauging be. Model: 1JankGauging Probe. Model i <br />EFX� Annular Space or Vault Sensor. Model: 794390-420 ❑ Annular Space or Vault Sensor. Model: <br />2 <br />e1iO Piping Sump / Trench Sensor(s). Model: 794380-205 ❑ Piping Sump/ Trench Sensor(s). Model: i( <br />4 <br />❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br />® Mechanical Line Leak Detector. Model: STP-MLLD-D ❑ Mechanical Line Leak Detector. Model: <br />TElectronic Line Leak Detector. Model: J❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High-l..evel Sensor. Model: ❑ Tank Overfill / High -Level Sensor. Model: <br />ijM Other (specify equipment type and model in Section E on Page 2). ❑ Other (specify equipment type and model in Section E on Page 2). <br />11 Tank ID: Tank ID: <br />[i <br />€❑ In -Tank Gauging Probe. Model: �❑ In=I'ankGauging Probe. Model: � <br />❑ Annular Space or Vault Sensor. Model: ® Annular Space or Vault Sensor. Model: <br />❑ Piping Sump / Trench Sensor(s). Model: ❑ Piping Sump / Trench Sensor(s). Model: <br />❑ Fill Sump Sensor(,). Model: ❑Fill Sump Sensor(,). Model: <br />II <br />❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: [I Electronic Line Leak Detector. Model: <br />E <br />IQTank Overfill/ High -Level Sensor. Model: ; ❑ Tank Overfill / High -Level Sensor. Model: <br />�'❑ Other (specify equipment type and model in Section E on Page 2) ❑ Other (spent} equipment type and model m Section E on Page 2) <br />_,.. _ <br />i�F7 Dispenser Containment Dispenser ID: Sensor(s). <br />Dis Dispenser ID: <br />Sensor(s). Model: 1❑ Dispenser Containment Senso s . Model: <br />�❑ Shear Valve(,). 1❑ Shear Valve(,). <br />❑ Dispenser Containment Float(s) and C'hain(s).❑ Dispenser Containment Float(s) and Chain(s). <br />9i <br />P (s) i <br />11Dispenser ID: (iDispenser ID: <br />0 Dispenser Containment Sensor(s). Model: li❑ Dispenser Containment Sensor(s). Model: <br />I_❑ Shear Valve(s). [i❑ Shear Valve(s). <br />i❑ Dispenser Containment Float(s) and Chain(s). ❑ Dispenser Containment Float(s) and Chain(s),I <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify, that this information is correctand <br />a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of <br />the report; (check all that apply) : ® System set-up Q Alarm history report <br />Technician Name (print): Victor Guerrero 1�a <br />Signature: <br />Certification No.: 836532 License. No.: 588098 <br />Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br />Testing Company Address: 2131 soUTirDUPONT DRIVE, ANAHEMI CA 92S06 Date of Testing/Servicing: 2015-11-23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.