My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2014-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2020 12:18:05 PM
Creation date
6/23/2020 6:53:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2018
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2014-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br />D. Results of Testing/Servicing DEC 0 9 2015 <br />Software Version Installed: 127.04 ENVIRONMENTAL <br />HI=AITW n=4 TUPRIT <br />Complete the following checklist: <br />_..._ ___._ ,..... _. ____ <br />�Q Yes 1 ❑ No* € 16, the audible alarm operational? { <br />❑X Yes ❑ No* Is the visual alarm operational? <br />r <br />Q Y❑Noes Were all sensors visually inspected,functionally tested and confirmed operational? <br />»w.,. <br />Were all interfere with No* sensors instal led at lowest of secondary containment and positioned so <br />QX Yes �, ❑ � p _that other equipment <br />will not i h their <br />i ro er o oration? <br />„4ake�,vv'2iWEki,�:�f��;�,���P,"•R`�",.ftS111;b3���` S?k4li, ,y. ����@ "�U��R)11FF� R \l,u"' 'd>a;:r1. <br />®i ® * If alarms are relayed to a remote monitoring statin is all communications equipment e. modem <br />Yes No 3( g ) E <br />Q N/A ; operational? <br />® Yes i ❑ No* For pressurized piping systems does the turbine automatically shut down if the piping secondary <br />containment monitoring system detects a leak, fails to operate, or is electrically disconnected9 dyes: which € <br />❑ N/A sensors initiate positive shut -down? (Check all that apply) <br />I <br />_ FXSump/Trench Sensors; ❑X Dispenser Containment Sensors. Did you confirm positive shut -down <br />due to leaks and sensor failure/disconnection?! <br />❑X Yes;❑No. <br />�❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the <br />❑X N/A tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? j <br />i <br />1 <br />o <br />/o _ <br />❑Yes* Q No a' Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br />replaced and list the manufacturer name and model for all replacement parts in Section E, below. <br />..._........................_ • _,....,,,,,,,. _. ._....... ,__.,.......,, ,,._ ..... <br />❑Yes* FX No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that <br />apply) ❑ Product; ❑ Water. If yes, describe causes in Section E, belov, <br />® Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />...__._._.._.._...._._._. _ _ _......... <br />_......... __....,. _.,.. _._.......... _._._..._......_..._.. a <br />® Yes ❑ No* Is all monitoring equipment operational per manufacturer's specificatrons� <br />In Section below, describe how and when these deficiencies were or <br />* will be corrected. <br />E. Comments: <br />Other sensors from page one: <br />L3 STP Sump 794380-205: Certified. <br />The drop tube is equipped with a mechanical overfill prevention valve. <br />
The URL can be used to link to this page
Your browser does not support the video tag.