Curved and Flat Alkhead Installation <br /> Step One <br /> Curved and Flat <br /> sumer"°` Choose the center pointfor the entry and drill a hole using a 6"hole saw <br /> °''• for the 5" bulkhead fitting, and a 3-1/2' hole saw for a 3" bulkhead <br /> fitting.After the hole is cut,file the edge to insure there are no burrs or <br /> excess pastic. Note: If drilling into a fiberglass sump, use carbide-tip <br /> hole saws. <br /> s ° <br /> S,,k,..d Step Two (Enviroflex only-3950 series) <br /> s"tt°„°` Curved and Flat <br /> Insertthe stiffener into thecorrugated secondary pipewhere applicable. <br /> Se d—Y Pipe <br /> SS Clemp Step Three <br /> Curved <br /> Remove the compression nut and the curved washer from the fitting. <br /> For added protection, prior to inserting the bulkhead, run a bead of <br /> Bostik 920 FS or equivalent around the outside sealing surface. Place <br /> J+ the bulkead through the entry from the outside, turning the bulkead to <br /> conform with the shape of the sump. Place the curved washer over the <br /> / bulkhead threads with the curved surface facing the sump wall. <br /> Nut <br /> W BthB' Balkh— J Flat <br /> Remove the compression nut and washer from the fitting. For added <br /> protection, prior to inserting the bulkhead, run a bead of Bostik 920 FS <br /> or equivalent around the outside sealing surface. Place the bulkead <br /> through the entry from the outside sealing surface. <br /> Step Four <br /> o.uae s„-ro Curved <br /> Ce�P 1� The washer and bulkhead fitting are molded to fit the curved surface of <br /> �1.. <br /> the sump. Be sure to position them correctly. Thread on the compres- <br /> sion nut and while holding from the outside, tighten on the inside <br /> compression nut between 21 and 25 foot pounds using a bulkhead <br /> wrench. Insert the pipe or conduit and tighten the stainless steel clamp <br /> B�,khe°a I between one and two foot ocunds around the pipe or conduiL a <br /> s�mpw n <br /> sbe ° —.. watertight seal. Fill the sump with water above the penetration to insure <br /> all fittings are watertight. <br /> FSI <br /> Thread on the compression nut and while holding from the outside, <br /> tighten on the inside compression nut between 21 and 25 foot pounds <br /> using a bulkhead wrench. Insert the pipe or conduit and tighten the <br /> stainless steel clamp between one and two foot pounds around the pipe <br /> or conduit for a watertight seal. Fill the sump with water above the <br /> penetration to insure all fittings are watertight. <br /> Note: Drawings show 5" fitting configuration. 3" fitting not shown. <br /> Page 3 - Bulkhead Fitting Installation <br />