Page_of <br /> 4. SECONDARY PIPE TESTING <br /> Test Method Developed By: ❑Piping Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ®Pressure ❑Vacuum ❑Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: DIAL GAUGE Equipment Resolution: .25 <br /> Piping Run# <br /> SUPPLY/RETURN Piping Run# Piping Run# Piping Run# <br /> SECONDARY#1171 <br /> Piping Material: COMPOSITE <br /> Piping Manufacturer: ENVIRO FLEX <br /> Piping Diameter: 4 INCHS <br /> Length of Piping Run: 70 FEET <br /> Product Stored: DIESEL <br /> Method and location of TEST BOOT IN <br /> piping-run isolation: SUMP <br /> Wait time between applying <br /> pressure/vacuum/water and 15 MIN. <br /> starting test: <br /> Test Start Time: 12:00 <br /> Initial Reading(RI): 5 PSI <br /> Test End Time: 1:00 <br /> Final Reading(RF): 5 PSI <br /> Test Duration: 1 HOUR <br /> Change in Reading(RF-RI): 0 <br /> Pass/Fail Threshold or 0 <br /> Criteria: <br /> Test Result: ® Pass ❑Fail ❑ Pass ❑Fail ❑ Pass' ❑Fail ❑ Pass ❑;Fail <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />