My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_1998-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:51:51 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2008
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_1998-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
354
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> Page of_ <br /> 7. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑ Other(Spec) <br /> Test Equipment Used: INCON TS-STS TEST UNIT Equipment Resolution: <br /> MENIMMEM <br /> Fill Sump#1171 Fill Sump# Fill Sump# Fill Sump# <br /> Sump Diameter: 44 INCHES <br /> Sump Depth: 80 INCHES <br /> Height from Tank Top to Top of 32 INCHES <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 31 INCHES <br /> Electrical Penetration: <br /> Condition of sump prior to GOOD <br /> testing: <br /> Portion of Sump Tested 2 INCHES ABOVE <br /> SUMPS HIGHEST <br /> PIPING <br /> PENETRATION <br /> Sump Material: PLASTIC <br /> Wait time between applying 15 MIN. <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: 10:06 AM 10:33 AM <br /> Initial Reading(Ri): 4.6017 4.8263 <br /> Test End Time: 10:21 AM 10:52 AM <br /> Final Reading(RF): 4.6031 4.8263 <br /> Test Duration: 15 MIN. 15 MIN. <br /> Change in Reading(RF-R,): .0014 .0000 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 <br /> Test Result: ® Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Is there a sensor in the sump? ®Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when ❑Yes ❑No ❑ <br /> either product or water is ®Yes ❑No ❑NA NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ❑Yes ❑No ❑ ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> NA <br /> Was sensor properly replaced and ®Yes ❑No ❑NA ❑Yes El No ❑ ❑Yes ❑No F1 NA ❑Yes ❑No ❑NA <br /> verified functional after testing? NA <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> FILL SUMP PASSED THE REQUIRED HYDROSTATIC TEST.NO REPAIR ARE NEEDED AT THE PRESENT TIME. <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.