My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:56:31 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D.Results of Testing/Servicing <br /> MAR 19 <br /> Software Version Installed: 121.00 2015 <br /> Complete the following checklist <br /> Yes No* �s the audiblealarm operational? <br /> 5 r E° ,t�\5k 'i"> 'K;C»¢fi ."� &9w..��wo. �. PvU`S'° ;YR1 / .`T" af,�". f � ,✓.Gay;? .f3i ��1`�ibxc'*.�' <br /> Yes !1 F No* ' Is the visual alarm operational? <br /> F Yes No* il Were all sensors visually inspected, functionally tested and confirmed operational? <br /> n of secondary containment andpositioned that other equ <br /> Yes No st <br /> * 1 Were all sensors installed at lowest poi t y p ipment <br /> will not interfere with their <br /> ro r o ration? <br /> .�•�' 0;.. 1 �R '.x �",4 ' NIIMM\ "3,*AZO; ,i Mall <br /> Yes 0 <br /> No* <br /> alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem) <br /> operational? <br /> r <br /> N/A ` <br /> Yes N o* For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> E containment monitoring system detects a leak,fails to operate, or is electrically disconnected?Ifyes: which <br /> N/A sensors initiate positive shut-down?(Check all that apply) <br /> ?) F Sump/TrenchSensors; Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to leaks and sensor failure/disconnection? <br /> Yes r No. <br /> __ <br /> Yes No* <br /> tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no € <br /> g mechanical overfill prevention valve is installed),is the overfill warningalarm visible and audible at the <br /> r y <br /> { N/A ,tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alarm trigger? j <br /> YL ( 1 <br /> % <br /> Yes* No Was any monitoring equipment replaced?If yes identify specific sensors probes or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E below. <br /> * y es,describe <br /> Was <br /> )�� found c <br /> � Yes � No inside an secondary containment systems designed as dry systems (Check all that <br /> apply) Product; Water.If y _causes in Section E below. <br /> Yes I No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports if applicable <br /> 4 <br /> Yes No* Is all monitoring equipment operational per manufacturer's specifications <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> An overfill prevention valve is installed in the drop tube. <br />
The URL can be used to link to this page
Your browser does not support the video tag.