My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2000
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AD ART
>
3330
>
2300 - Underground Storage Tank Program
>
PR0231901
>
COMPLIANCE INFO_1986-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2024 1:44:19 PM
Creation date
6/23/2020 6:53:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2000
RECORD_ID
PR0231901
PE
2361
FACILITY_ID
FA0003825
FACILITY_NAME
CALIFORNIA HIGHWAY PATROL #265*
STREET_NUMBER
3330
Direction
N
STREET_NAME
AD ART
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
3330 N AD ART RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231901_3330 N AD ART_1986-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
308
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-THE RED JAGKET 3 -STEP-` <br />I LEAK TEST <br />The Red Jacket leak detector is a pres- <br />sure sensing, diaphragm operated valve <br />designed to indicate a leak in the piping <br />between the leak detector and dispenser. <br />When the submerged pump is turned <br />on, a controlled amount of product <br />(three gallons per hour) is metered <br />through the leak detector Into the pip- <br />ing system. If a leak is present which <br />POSITION t <br />LESS THAN 1 PSI <br />FULL PRESSURE <br />APPROX. 25 PSI <br />FROM PUMP <br />ME <br />THE "TRIP" OR RELAXED POSITION. <br />Under normal operating conditions, it <br />is assumed that the lines are filled <br />with gasoline. When the system pres- <br />sure is less than 1 psi, the diaphragm <br />and poppet are in their "down" or <br />"tripped" position. The position of <br />the valve "poppet' is such as to allow <br />approximately 11/2 to 3 gpm flow into <br />the delivery line, through a bypass <br />opening in the leak detector valve <br />poppet, when the submersible pump <br />starts. Since the system is full, pres- <br />sure builds rapidly and the poppet <br />moves to the leak sensing position <br />assuming there is no leak present. <br />LEAK SENSING POSITION. As the <br />pressure builds to approximately 8 to <br />10 psi (rapidly), the diaphragm has <br />moved the "poppet' to such a posi- <br />equals or exceeds this amount, as <br />much product escapes from the sys- <br />tem as is metered in through the leak <br />detector. Under this condition pressure <br />cannot build up in the piping system. <br />When a nozzle is opened a poppet in <br />the leak detector moves to a position <br />which restricts the flow to approximate- <br />ly 11/2-3 GPM. This is the indication to <br />tion as to almost stop the flow into <br />the piping through the leak detector <br />valve poppet. In this position, all the <br />flow must then travel around the me. <br />tering pin which limits it to approxi- <br />mately 3 gph rate. If a simultaneous <br />loss from the system equals or ex- <br />ceeds this amount, the line pressure <br />will not build beyond this point and <br />the valve will remain in the leak sens- <br />ing position with the main flog <br />blocked. If there is an attempt to dis- <br />pense while the valve is in this posi- <br />tion, the line pressure will drop, the <br />diaphragm will respond, and the pop- <br />pet will return to position 1 where 11/2 <br />to 3 gpm will flow to the dispensers. <br />Leaks smaller than 3 gph will be indi- <br />cated by the Leak Detector taking <br />longer than approximately two sec - <br />11 <br />the operator that a leak is present. <br />If there are no leaks, pressure rapid- <br />ly builds in the system forcing the leak <br />detector to open to the full -flow posi- <br />tion. In a system with no leaks it takes <br />approximately two seconds for a com- <br />plete test. No further line testing takes <br />place until the line pressure drops <br />below 1 PSI. <br />MARLEY <br />THE MARLEY PUMP COMPANY <br />RED JACKET PUMPS <br />5800 Fo.ridge Dr., Mission. KS 66202 19131 722 1485 <br />In Canada - Marley Fluid S,•srems. 126 East Dr., Brampton, Ontario L6T 1C2 <br />International Sales - Missiu.r. KS Tele. 716875045 MARLY UW <br />POSITION 9 <br />.' FULL PRESSURE <br />APPROX. 25 PSI <br />FROM PUMP <br />y <br />ALL PRESSU+E <br />EQUAL <br />onds to open completely. If there is <br />no leakage in the system, the small <br />flow around the metering pin in- <br />creases the line pressure to 10 psi in <br />approximately two seconds at which <br />point the diaphragm will snap the <br />poppet to position 3. This all takes <br />place in less time than it takes to re- <br />set the dispenser, walk to the car, re- <br />move the gas tank cap, insert and <br />open the nozzle. <br />NON -LEAK POSITION. This position <br />allows full flow. The poppet will re- <br />main in this position as long as the <br />system pressure remains above 1 psi. <br />At less than 1 psi the poppet will re- <br />turn to position 1 and the next time <br />the pump is activated, the Leak De- <br />tector will perform a line test. <br />Form No. 5170 Rev. 2/87 <br />
The URL can be used to link to this page
Your browser does not support the video tag.