by GR Job 9 20-641524 <br /> C) Emergency Shut-Off (ESO) Testing Results & Checklist <br /> Facility Information Contractor Information TEST Results <br /> Site# Arco SS 5450 Co. Name: Gettler-Ryan Inc. Date: <br /> Address: 1617 W.Fremont Phone 925-551-7555 <br /> Ci /St: Stockton,CA Lead Technician: Elodio Sanchez x PASS <br /> eMaint W.O.# 10045909 Name: or <br /> Passport: FAIL(Next Day Repair Required) <br /> Signature <br /> The objective of this test Is to provide assurance that the when the E-Stop switch Is activated,all the fueling system circuits(turbines,and dispensers)are de-energized,and <br /> remain de-energized until they are re-set manually). The test procedures and guidelines shall be in accordance with the Estop Testing Process. <br /> N The fo/lowlng,Intonation is to be completed. x TO sweet <br /> Yes I No I WA <br /> SITE DATA p <br /> 1 Number of E-Stop switches: 2 <br /> 2 Type of Switch? Push Pull x Momentary_ Plain light/Toggle_ Other: <br /> (if Momentary type,locate and identify re-set button): In Elect Room " <br /> 3 Type of Turbine Control Relay System(Electrical Distribution Center): # . <br /> _Brown Box _Power Solution x Other _Custom Fabricated <br /> 4 Type of Turbine Control Relays: Make Fe Petro Model MAG VFC <br /> 5 Type of Line Leak Detection: Mechanical ELD/CPT x PLLD <br /> PERFORMANCE TEST <br /> 8 Does the E-Stop shutdown power to the DISPENSERS x <br /> 7 Does the E-Stop shutdown power to the TURBINES x <br /> 8 Is the 220 voltage to the turbine relay removed(either the line side or the motor side of the contacts or the coil)? x <br /> 9 Are the DISPENSER BREAKERS clearly identified/labeled? x <br /> 10 Are the TURBINE BREAKERS clearly identified/labeled? x <br /> 11 Are all the ESOs accessible and clearly identified/labeled? x <br /> 12 Did the ESO(s)function correctly(de-energized from either the line side or the motor side of the contacts or the coil)? x <br /> 12A If#12 is NO,briefly describe what was wrong: <br /> 12B How was it corrected: <br /> 12C If repair or ESO functionality cannot be corrected same day(prior to leaving the site). The technician MUST notify the Site <br /> Manager of the problem, place an"Out of Service"Tag on the ESO(s),and identify an alternate mean(i.e.,locate circuit <br /> panel,clearly identify turbine and dispenser breakers for shut-off in the event of an emergency). <br /> 12D Elite Customer Solution Center has been contacted for the repair. <br /> eMaint.W.O.Ticket# <br /> I MANOR <br /> POST TEST <br /> 11 Site's fueling system is fully operational. ]X;x 12 All equipment secured and any access ports,lids,enclosures are closed.13 All safety barricades,and any debris was been removed. <br /> COMMENTS <br /> Submit completed copy with other documentation In E-Maintenance. <br />