Laserfiche WebLink
SWRCB,January 2002 JUN 0 12016 Page_6_of—7- <br /> 8. FILL RISER CONTAINMENT SUMP K &G&16r. •- <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ 1.L N %-a. <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer N Industry Standard ❑ Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑ Vacuum N Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: INCON SUMP TESTER Equipment Resolution:+/-0.002" <br /> Fill Sump#87 MAIN Fill Sump#87 Fill Sump#91 Fill Sump# <br /> MANIFOLD <br /> Sum,Diameter: 42" 42" 42" <br /> Sump Depth: 58" 59" 61" <br /> Height from Tank Top to Top of NIA NIA N/A <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 28„ 31" 31" <br /> Electrical Penetration: <br /> Condition of sump prior to DIRTY DIRTY DIRTY <br /> testing: <br /> Portion of Sump Tested 2"ABOVE 2"ABOVE 2"ABOVE <br /> PENETRATION PENETRATION PENETRATION <br /> Sump Material: FIBERGLASS FIBERGLASS FIBERGLASS <br /> Wait time between applying <br /> pressure/vacuum/water and 30 MIN 30 MIN VISUAL FAIL <br /> starting test: <br /> Test Start Time: 11:22 1:38 <br /> Initial Reading(R,): 4.7063" 5.6529" <br /> Test End Time: 11:37 1:53 <br /> Final Reading(RF): 4.7062" 5.6493" <br /> Test Duration: 15 MIN 15 MIN <br /> Change in Reading(RF-RI): -0.00011, -0.0036" <br /> Pass/Fail Threshold or Criteria: +/-0.002" +1-0.002" +/-0.002" +/-0.002" <br /> Test Result; M Pass El Fail ❑Pass N Fail ❑Pass g Fail ❑ Pass [] Fail <br /> Is there a sensor in the sump? N Yes ❑ No N Yes ❑No N Yes ❑No ❑Yes ❑ No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No ENA Elves ❑No N NA [:]Yes ❑No [DNA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? N Yes ❑No ❑NA N Yes ❑No ❑NA N Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? ®Yes E]No ❑NA N Yes ❑No ❑NA N Yes ❑No ❑NA ❑Yes El No ❑NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br /> 87 MANIFOLD FILL SUMP FAILED-NO VISUAL LEAKS <br /> MAY NEED TO TIGHTEN ELECTRICAL PENETRATIONS <br /> 91 FILL SUMP HAD VISUAL FAIL-WATER LEVEL DROPPED WITHIN 30 MINUTE WAIT TIME-RIPPED ELECTRICAL <br /> PENETRATION <br /> WILL NEED TO REPLACE BOTH ELECTRICAL PENETRATIONS(ONE IS ANGLE) <br />