My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:13:57 PM
Creation date
6/23/2020 6:54:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® GETrLEB-RYAN INC, GR Job# 1820. 1728 <br /> D. Results of Testing/Servicing SWRCB,January 2006 <br /> Software version Installed: 3 3 3 . 0 5 <br /> Complete the following checklist <br /> Q o Is the audible alarm operational? <br /> 0 Yes D No' is the visual alarm operational? <br /> ® Yes E3 No* Were all sensors visually inspected,functionally tasted,and confirmed operational? <br /> 0 Yes 0 No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> ror o ration? <br /> m Yes 13 No' If alarms are relayed to a remote monitoring station,is all communication equipment(e.g.modem)operational? <br /> 13 N/A <br /> @ Yes ❑ No' For pressurized piping systems,dues the turbine automati ly shut down if the piping secondary containment monitoring system <br /> 0 N/A detects a leak,fads to operate,or is electrically disconnected?tf yea:which sensors initiate positive shut-down?(Check all Met apply) <br /> 0 Sump/Trench Sensor; ® Dispenser Containment Sensor.Did you confine positive shut-down due to leaks and sensor <br /> fadure/disconnection? M Yes; ® No. <br /> ® Yes [3 No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(.e.no mechanical overfill prevention <br /> (3 N/A valve is installed),is the overfill warning alarm visible and audible at the tank fid point(s)and operating properly?If so,at what percent <br /> of tank capacity does the alarm trigger? .25 % <br /> ® Yes ® No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and fist the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> ® Yes ® No Was liquid found inside any secondary containment systems designed as dry systems? Check all that apply) QProducty [3Water. If <br /> M describe causes in Section E,below. <br /> ® Yes E3 No' Was monitoring system set-up reviewed to Insure proper settings?Attach set-up reports,if applicable. <br /> 10 Yes ❑ No' I Is all monitoring equipment operational per manufacture's specifications? <br /> •In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Monitoring System Certification Page 2 of 4 12107 <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.