My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
205
>
2300 - Underground Storage Tank Program
>
PR0232257
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 8:15:16 AM
Creation date
6/23/2020 6:54:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0232257
PE
2361
FACILITY_ID
FA0000670
FACILITY_NAME
QUIK STOP MARKET #3148*
STREET_NUMBER
205
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04116115
CURRENT_STATUS
01
SITE_LOCATION
205 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232257_205 W LOCKEFORD_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPA TMENT <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- Pa e 1 of 2) <br /> TYPE OF ACTION 1.NEW FORMAT ❑ 2.CHANGE OF INFORMATION 490-1 <br /> PLAN TYPE W1 MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2 <br /> (Check one item only) ❑ 2 THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEMS) <br /> FACILITY ID#(Agency Use Only) l 1 <br /> BUSINESS NAME(Same as FACILITY NAME) QUIK STOP MARKET#148 N 3. <br /> BUSINESS SITE ADDRESS 205 W.LOCKEFORD STREET 103CITY LODI,CA 95240 104. <br /> : .. �� �T•)S3 a'�G�A�ND�P._ .�', �'' � E N✓ GL � <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> 23 CCR 2632, ,26342638,2641) _ --------- <br /> - <br /> MONITORING EQUIPMENT IS SERVICED 1.ANNUALLY El99.OTHER S eci 4901-39 <br /> ( P fY)� 0-901-3b <br /> ❑1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. K2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)490.4 <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 490-5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL S. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: Ira.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 490-6 <br /> _PANEL MANUFACTURER: VEEDER-ROOT "' MODEL#: TIS-350 490-8 <br /> LEAK SENSOR MANUFACTURER: VEEDER-ROOT 49°'9 MODEL#(S): 0794390409 490-101 <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(Sl.(23 CCR§2643) 490-11 <br /> PANEL MANUFACTURER: 490-12" MODEL#: _- 490-13 <br /> 0-90-14. #(S): 1490-15 <br /> _ _IN-TANK PROBE MANUFACTURER: MODEL <br /> LEAK TEST FREQUENCY: [3a.CONTINUOUS C] b.DAILY/NIGHTLY ❑ c.WEEKLY 490-1 <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): _ 490-177 <br /> 0-901-10- <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 490-19 <br /> ❑ 3.MONTHLY STATISTICAL EqVENTORY RECONCILIATION(23 CCR§2646.1): 490.20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: ❑ a.36 HOURS C1b.60 HOURS 490-21 <br /> ago.zz <br /> 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 490.23 <br /> TEST FREQUENCY: C1 a.ANNUALLY El b.BIENNIALLY ❑ c.OTHER(Specify): antis <br /> 490-26 <br /> ❑ <br /> 99.OTHER (Specify): 490-27 <br /> �(Cfieckallthat?a 1 <br /> 1.CONTINUOUS MONITORING vOFPIPEI PIPING SUMP( AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 490-28 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS: a.DRY ❑b.LIQUID FILLED ❑c.PRESSURIZED ❑d.UNDER VACUUM 490-39 <br /> __PANEL MANUFACTURER: VEEDER-ROOT 430 MODEL#: TLS-350^ 4s°-31 <br /> LEAK SENSOR MANUFACTURER: VEEDER-ROOT 490-32 I .MODEL#(S): 0794380-208 _ 490-33 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ••• ate.YES C1 b.NO 490-35 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. llSa.YES C1 b.NO ago-3s <br /> 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> _ <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED(23 CCR§2636) 490-36 <br /> MLLD MANUFACTURER(S): VAPORLESS&RED JACKET 490-37 MODEL#(S): 99LD2000&FX 490.38 <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490-39 <br /> 411. i MODEL#(S): 490-41 <br /> ELLD MANUFACTURER(S) --_ ._i_. ( ) <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. F-12.MINIMUM ANNUAL 0.1 g.p.h. 49x43 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 0-901-43 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49044 <br /> 4.PIPE INTEGRITY TESTING 490145 <br /> TEST FREQUENCY ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 49046490-47 <br /> 5.VISUAL PIPE MONTTORING. 49048 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑C.MEN.MONTHLY&EACH TIME SYSTEM OPERATED' 490.49 <br /> • <br /> All for monitoring of unburied emallency mentor fud piping only HSC 25281.5 3 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR§2636(a)(3)]. 490-50 <br /> 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 590-51 <br /> 0-90-93 <br /> C199.OTHER(Specify) 490-53 <br /> UPCF UST-D(12/2007)1/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.