a a <br /> SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> 1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 490-54. <br /> ,�,� 490.546 <br /> C11.CONTINUOUS ELECTRONIC MONITORING l�7 2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE <br /> ❑4.NO DISPENSERS ❑99.OTHER(Specify): <br /> PANEL MANUFACTURER: 4w5 Ms ODEL#: 490-56. <br /> LEAK SENSOR MANUFACTURER: 457 MODEL#(S): a�ss <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑ a.YES .,//b.NO 49°x9 <br /> R <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ❑ a.YES b.NO 490-60. <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES eb.NO 490-61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. a.YES ❑b.NO 490.62 <br /> 2.UDC CONSTRUCTION IS 1.SINGLE-WALLED ❑2.DOUBLE-WALLED 490-63 <br /> IF DOUBLE WALLED: 490-64a <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑I.LI UID ❑2.PRESSURE ❑3.VACUUM _ <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLEANDVISUAL ALARMS ❑a.YES ❑b.NO 490-64b <br /> LJ <br /> 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 490.65. <br /> LgAK DETECTION fELDI MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 2�3 CCR§2644.1) _ <br /> 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. _ 490-66 <br /> 3.SPILL BUCKETS ARE TESTED ANNUALLY. 490.67 <br /> The following monitoring/maiv nance records are kept for flus facility: <br /> (Alarm logs 490-68A isual Inspection Records 4go-6ab ❑Tank integrity testing results 490-680 <br /> ❑SIR testing results(and supporting documentation records). 490-68d ❑ Tank gauging results(and supporting documentation records). ago-6s* <br /> ❑ATG Testing results(and supporting documentation records).4go-6sf ❑ Corrosion Protection 60-day logs 490-68a <br /> Equipment maintenance and calibration records. 490-6sh <br /> l? <br /> ,s -•. .,w �.a^kiiis .c,n�u�a.,t,��..:�ta�s., <br /> ,.., .n..�,. a., �„ <br /> Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 490-69a <br /> REFS NCE DOCUMENTS MAINTAINED AT FACILITY(Check all drat apply) <br /> THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)4go-6% <br /> ❑ OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)490-690 <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-69d <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 490-69* <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"4go-69f <br /> ❑1SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490-694 <br /> OTHER(Specify):M6gh,M6gi "Written Procedures&Best Management Practices for Monitoring Double Containment UST Systems" <br /> This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> Operation of the UST systems in a manner consistent with the facility's best management practices <br /> A The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> The facility employee's role with regard to spills and overfills as specified in the UST Response Pian <br /> A Names of contact person(s)for emergencies and monitoring alarms.49o-7o <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan.490-71 <br /> OVERFILL PREVENTION(OR PROTECTION)IS ACCOMPLISHED BY THE FOLLOWING TWO(2)METHODS: <br /> 1. MECHANICAL OVERFILL VALVES INSTALLED IN DROP TUBES,SET TO TRIP AT 95%TANK CAPACITY <br /> 2. SERVICE PENETRATIONS TO THE PR54ARY CONTAINMENT ARE CONTAINED WITHIN SUMPS INCLUDING FILL&VAPOR RETURN <br /> The UST Owner/Operator is responsible for ensuring that:1)the daily/routine UST monitoring activities and maintenance of UST teak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The following person(s)are responsible for performing the monitoring and equipment maintenance: <br /> NAME MOTA&RAJINDER SANGHERA 490-72 TITLE FRANCHISEES 490-73 <br /> NAME SAMI ALKOUSSA 490-74 TITLE DISTRICT ADVISOR 490-75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility,provide a report to the owner/operator,and inform the owner/opemtor of any <br /> conditions that need follow-up action. <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATURE 490-76 DATE: ag0-77 <br /> SEPTEMBER 3,2009 <br /> r❑ <br /> APPLICANT NAME(print): 4118 APPLICANT TITLE: 49479 <br /> MIKE KARVELOT,for Quik Stop Markets,Inc. DIRECTOR,ENVIRONMENTAL AFFAIRS <br /> UPCF UST-D(12/2007)3/4 <br />