My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
147
>
2300 - Underground Storage Tank Program
>
PR0232353
>
COMPLIANCE INFO_1988-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2024 9:38:51 AM
Creation date
6/23/2020 6:54:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2007
RECORD_ID
PR0232353
PE
2361
FACILITY_ID
FA0003789
FACILITY_NAME
TWO GUYS FOOD & FUEL
STREET_NUMBER
147
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19608071
CURRENT_STATUS
01
SITE_LOCATION
147 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232353_147 E LATHROP_1988-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
409
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> - Flashing 84 Alarm error code Q2 What should I do if a line leak test fails ? <br /> The line is Out of Compliance—this alarm cannot be A2 Contact your local inspection agency as required TS LLD <br /> Leak Test Failures: reset(33 or more days have elapsed since a 0.2 gph, <br /> test has passed).Product dis ens- by State Laws and Regulations.Inspect the <br /> monthly-compliance <br /> FLASHING 3 ALARM CODEp ) p dispense area and hose(s)for leaks.If there is a <br /> ing is not allowed when Out of Compliance.A new 0.2 <br /> A 3 gph line leak was detected(hourly test failed). gph test automatically starts when this alarm is displayed leak then go to A3 and follow those directions. If <br /> quick <br /> FLASHING 2 ALARM CODE —Prevent dispensing to give the test time to finish(13 then <br /> obvious leaks exist Press RESET-TEST, <br /> then raise and lower the <br /> dispense handle to start <br /> A 0.2 gph line leak was detected(monthly test failed). minutes to 4 hours). automatic leak tests(or start a manual test)toReference <br /> FLASHING 1 ALARM CODE Flashing 85 Alarm error Cade verify the first failure. <br /> A 0.1 gph line leak was detected(manual test failed). The Leak Sensing Unit needs maintenance—push Note Line leak tests may occasionally fail when no e <br /> leaks exist because of. product line instability, 4 <br /> "Ll�RESET for a permissive dispense grace period—and <br /> When a leak test fails: call for service. pump malfunction,or vapor recovery system <br /> 1) product dispensing is not permitted unless the malfunction.Therefore,your service provider maymom <br /> RESET-TEST button is pushed(to retest) K ask you to push RESET to retest the line for leaks. f <br /> 2) The LINE LEAK DETECTED light will keep 03 What if the line leak test fails again ? <br /> flashing until another equivalent test passes A.) Two seconds after power is applied,the display will <br /> show the version number of the Control Unit,and A3 Contact your local inspection agency as required <br /> When Flashing Alarm I then the version number of the Leak Sensing Unit. w by State Laws and Regulations.Inspect for leaks, <br /> g stop dispensing,and turn off all power to that l <br /> Error Codes occur: B.) Pushing the RESET-TEST button repeatedly dispenser and submersible pump. Call INCON, <br /> DO record the Flashing Alarm Error Code numbers causes the control unit to display several different <br /> g or your local distributor for help with line leak <br /> in your error log. DO see the 0&A section about codes: � failures. <br /> What to do If a LeakTest Fails. DO call for service if 1st push: An 88 is displayed(if the system is OK) Follow the advice carefully and accurately. CO <br /> any leak alarm occurs. DO follow the directions <br /> 2nd push: A factory diagnostic code is displayed TS-LLt3 <br /> noted here for other flashing alarms. l LINE LEAK DETEcTOP <br /> 3rd push: Another diagnostic code is displayed <br /> o.—Y FUNCTioor <br /> Flashing 80 Alarm error code 4th push: The most recent Flashing Alarm error NORMAL: DAYS SINCE MONTHLY LEAK TEST P-] <br /> SSED <br /> Amanually-started annual test was aborted because a code is displayed <br /> FLASHING:2.FAILED ANNUAL(D.f GPH)LEAK TEST <br /> Copy the Name and phone number of your local 2•FAILED MONTHLY(0.2 GPH)LEAK TEST ". <br /> dispense was attempted—push RESET to allow 3.FAILED"°COMP(3.0 GP"'LEAK TEST ' <br /> Inspection Agency,local Distributor and Service 23-32.MONTHLY COMPLIANCE WARNING <br /> p g y, 33-87.ERROR CODES <br /> dispensing and see "Normal Operation#4)"about the SS.SYSTEM OK PRESS TEST TO ACTIVATE) <br /> requirements of and how to start a manual test. ` ' ' provider(s)in the box below. i RESET <br /> f TEST PRESS RESE7 TO CLEAR ALARM <br /> I PRESS TEST FOR 5 SECONDS TO RUN ANNUAL TEST <br /> Flashing 81 Alarm error code 01 Why does the display count up days?–or– <br /> A component failed in the Leak Sensing Unit—push Why do monthly tests take days to finish ? <br /> RESET to allow dispensing—and call for service. Al Days count up,or tests don't finish because: <br /> a) Test-times have increased(unstable thermal <br /> Flashing 82 Alarm error code conditions exist within the fuel line) and/or <br /> A leak test was aborted because the system was net b) Dispensing occurs too frequently(quiet- <br /> time is too short)—tests automatically abort <br /> thermally stable—push RESET to allow dispensing. when product is dispensed. x " <br /> Flashing 83 Alarm error code Note: This guide is for use with Control Unit version <br /> The Leak Sensing Unit is not communicating with the numbers 3.2,and greater...see"Diagnostics# Need help or service? Call INCON @ 1-800- <br /> Control Unit—push RESET for a permissive dispense A"(above). 984-6266 for the name and number of the nearest <br /> grace period—and call for service. INCON Part Number 000-1447 Rev.11 b TS-LLD distributor/service organization. <br /> I <br />