My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
147
>
2300 - Underground Storage Tank Program
>
PR0232353
>
COMPLIANCE INFO_1988-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2024 9:38:51 AM
Creation date
6/23/2020 6:54:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2007
RECORD_ID
PR0232353
PE
2361
FACILITY_ID
FA0003789
FACILITY_NAME
TWO GUYS FOOD & FUEL
STREET_NUMBER
147
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19608071
CURRENT_STATUS
01
SITE_LOCATION
147 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232353_147 E LATHROP_1988-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
409
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CCR,TITLE 23, DIVISION 3, CHAPTER 16, UNDERGROUND STORAGE TANK REGULATIONS CCR, TITLE 23, DLvISION 3, CHAPTER 16, UNDERGROUND STORAGE TANK REGUTATIONS <br /> (C) No valves or pumps are installed below grade in the suction line. percent of design operating pressure or pneumatically at 110 percent of design <br /> Only one check valve is located directly below and as close as operating pressure. If the calculated test pressure for pressurized piping is less <br /> practical to the suction pump; than 40 psi, 40 psi shall be used as the test pressure. The pressure shall be <br /> maintained for a minimum of 30 minutes and all joints shall be soap tested. A <br /> (D)An inspection method is provided which readily demonstra,.ts failed test,as evidenced by the presence of bubbles,shall require appropriate <br /> compliance with subdivisions(A)through (C) above. repairs and retesting. If there are no manufacturers guidelines,secondary <br /> containment systems shall be tested using an applicable method specified in an <br /> (b) All corrodible underground piping, if in direct contact with backfill material, industry code or engineering standard. Suction piping and gravity flow piping <br /> shall be protected against corrosion.Piping constructed of fiberglass-reinforced which cannot be isolated from the tank shall be tested after installation in <br /> plastic,steel with cathodic protection, or steel isolated from direct contact with conjunction with an overfilled volumetric tank integrity test,or other test <br /> backfill, fulfills this corrosion protection requirement. Cathodic protection shall method meeting the requirements of section 2643(0,if approved by the local <br /> meet the requirements of section 2635(a)(2). agency. <br /> (c) Underground primary piping shall meet all of the following requirements: (f) Underground piping with secondary containment shall be equipped and <br /> monitored as follows: <br /> (1) Primary piping in contact with hazardous substances under normal <br /> operating conditions shall be installed inside a secondary containment (1) The secondary containment system shall be equipped with a <br /> system which may be a secondary pipe,vault,or a lined trench. All continuous monitoring system which meets the requirements of <br /> secondary containment systems shall be sloped so that all releases will section 2643(f) and which is connected to an audible and visual alarm <br /> flow to a collection sump located at the low point of the underground system. <br /> piping. <br /> (2) Automatic line leak detectors shall be installed on underground <br /> (2) Primary piping and secondary containment systems shall be installed pressurized piping and shall be capable of detecting a 3-gallon per <br /> In accordance with an industry code of practice developed in hour leak rate at 10 psi within 1 hour with a probability of detection <br /> accordance with voluntary consensus standards. The owner or of at least 95 percent and a probability of false alarm no greater than 5 <br /> operator shall certify that the piping was installed in accordance with percent. Compliance with these standards shall be certified in <br /> the above requirements of section 2635(d). The certification shall be accordance with section 2643(17 of Article 4. <br /> made on the"Certification of Compliance for Underground Storage <br /> Tank Installation Form C" (see Appendix V). (3) Other monitoring methods may be used in lieu of the requirement in <br /> subdivision(2) if it is demonstrated to the satisfaction of the local <br /> (d) Lined trench systems used as part of a secondary containment system shall be agency that the alternate method is as effective as the methods <br /> designed and constructed according to a code of practice or engineering otherwise required by this section. A continuous monitoring system <br /> standard approved by a state registered professional engineer. The following as described in subdivision (1),which shuts down the pump in <br /> requirements shall also apply: addition to:activating the alarm system,satisfies the automatic line leak <br /> detector requirement of subdivision(2). <br /> (1) All trench materials shall be compatible with the substance stored and <br /> evaluated by an independent testing organization for their (4) Monitoring shall be conducted on all underground pressurized piping <br /> compatibility or adequacy of the trench design,construction, and with secondary containment at least annually at a pressure designated <br /> application. by the equipment manufacturer,provided that the method is capable <br /> of detecting a minimum release equivalent to 0.1 gallon per hour <br /> (2) The trench shall be covered and capable of supporting any expected defined at 1.50 percent of the normal operating pressure of the <br /> vehicular traffic. product piping system at the test pressure with at least a 95 percent <br /> probability of detection and not more than a 5 percent probability of <br /> (e) All new primary piping and secondary containment systems shall be tested for false alarm. This requirement is waived if the criteria in subsection(g) <br /> tightness after installation in accordance with manufacturer's guidelines. of this section are met. <br /> Primary pressurized piping shall be tested for tightness hydrostatically at 150 <br /> 3-17 3-18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.