San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sl4ov.org/ehd <br /> Underground Storage Tank Progra>l^ [ns�ection Report <br /> Facility Name: Facility Address: Date: <br /> TWO GUYS FOOD& FUEL 147 E LATHROP RD, LATHROP June 08,2017 <br /> EtS C_ystem Observations <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> $n [e-Walled ---7,P-- <br /> 16 Plpttg <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> aother Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> 7777 <br /> IJMMARY OF UIQ:LATiQNS <br /> (Gf 1 i,CLASS 11,or MINOR-Notieo to Complli4}1 <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for the 87, 91, and diesel tanks are not current in CERS. Beneath"Tank Construction," <br /> change the"Primary Containment"from"Fiberglass"to"Steel"for all three tanks. Any change of information must <br /> be updated in CERS within 30 days of the changes. Immediately log into CERS, update the required information, <br /> and submit for review by the EHD. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 105 CCR 2632(d)(1)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. In the"Monitoring Plan,"beneath"Under <br /> Dispenser Containment(UDC)Monitoring), change"Leak Within Secondary Containment of UDC Causes Audible <br /> and Visual Alarms"from"Yes"to"No"for all three tanks. The monitoring plan must be uploaded to the California <br /> Environmental Reporting System(CERS). Immediately log into CERS, make the necessary changes, and submit <br /> for review by the EHD. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> FA0003789 PR0232353 SCO01 06/08/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 4 Underground Storage Tank Program OIR <br />