Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TWO GUYS FOOD& FUEL 147 E LATHROP RD, LATHROP June 08,2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS It,or MINOR,-Notice to Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted.Add an"X"in each annular space to indicate the location <br /> of each annular sensor. Add an"L"in each submersible turbine pump sump to indicate the location of each line leak <br /> detector. On the Key, add"L=Line Leak Detector."A site plan must be submitted identifying the locations where <br /> monitoring will be performed. Immediately log into the California Environmental Reporting System(CERS)at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to provide the alarm history for the L6 sensor in the 87-product submersible turbine <br /> pump sump during the July 22,2016 designated operator monthly inspection report. During the monthly inspection, <br /> the designated operator shall review the alarm history for the previous month, check that each alarm was <br /> documented and responded to appropriately, and attach a copy of the alarm history with documentation taken in <br /> response to any alarms to the monthly report. Ensure that designated operators performing monthly inspections at <br /> this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by July 8, 2017. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Note: In CERS under"UST Certification of Financial Responsibility", the submittal needs to be removed and <br /> replaced with the Certification of Financial Responsibility found in"UST Letter from Chief Financial Officer."The <br /> latter contains the correct financial responsibility of 1 million dollars per occurrence, instead of 500,000 dollars <br /> per occurrence. <br /> AFTER THE COMPLIANCE DATE,EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: June 08, 2017 Inspector: Inspector Phone: <br /> Printed Name and Title: ELIANNA FLORIDO, EHS Trainee (209)468-0343 <br /> Frank Kamboj, Owner <br /> FA0003789 PR0232353 SC001 06/08/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 4 Underground Storage Tank Program OIR <br />