Laserfiche WebLink
dh <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> s <br /> Facility Name: "25121 <br /> ess: Date: <br /> WATERLOO LIQUOR TERLOO RD STOCKTON Aril 12 2016 <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump ❑V ❑R ❑COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V ❑R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ❑V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V ❑R ❑COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R ❑COS <br /> 329 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 332 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 2010See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> PO4 <br /> Remarks <br /> CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br /> UST Tank Information forms for all three tanks are not current in CERS. All three tanks, 87, 91 and diesel, listed the <br /> vent secondary containment and riser secondary containment as fiberglass but field verification indicated no <br /> secondary containment for either vent or riser. For all three tanks, fill component installed for containment sump was <br /> listed as yes, but field verification indicated no containment sumps for all three tanks. For 91 and diesel construction <br /> material of under dispenser containment, it is listed as steel when field verification indicated fiberglass. Any change of <br /> information must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the required <br /> information, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> Page 3 of 5 <br />