My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2512
>
2300 - Underground Storage Tank Program
>
PR0232418
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:16:02 PM
Creation date
6/23/2020 6:55:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232418
PE
2361
FACILITY_ID
FA0004064
FACILITY_NAME
WATERLOO LIQUOR
STREET_NUMBER
2512
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14128102
CURRENT_STATUS
01
SITE_LOCATION
2512 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232418_2512 E WATERLOO_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
429
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
lqW <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Facility Name: Facility Address: Date: <br /> WATERLOO LIQUOR 2512 E WATERLOO RD STOCKTON Aril 12 2016 <br /> SUMMARY OF VIOL) i IN` <br /> (CLASS 1, or MINOR <br /> Item# Remarks <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plans of 87 and 91 did not indicate <br /> the following: 1) if a leak alarm will trigger automatic pump shutdown 2) a failure or disconnect will trigger pump <br /> shutdown 3) mechanical or electronic leak detector manufacturer and model. The monitoring plan of diesel did not <br /> indicate leak detector manufacturer and model. The monitoring plan must be uploaded to the California Environmental <br /> Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> The response plan is not current and/or not approved by the EHD. The response plan must be uploaded to the <br /> California Environmental Reporting System (CERS). Immediately log into CERS, upload the completed form, and <br /> submit for review by the EHD. Ensure a copy is available for inspection at any time. <br /> This is a repeat violation, Class II. <br /> 126 HSC 25404(e)(4) Failed to report program data electronically. <br /> The UST response plan was not submitted to the the California Electronic Reporting System (CERS). Beginning <br /> January 1, 2014, all businesses are required to submit all new(or any changes to existing) UST information, including: <br /> UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST Response Plan, UST Owner/Operator <br /> Written Agreement(if applicable), UST Letter from Chief Financial Officer, and Owner Statement of Designated UST <br /> Operator Compliance online to the CERS at http://cers.calepa.ca.gov. Be sure to include any other relevant activities <br /> and required fields. <br /> This is a minor violation. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. Monitoring system certification <br /> test results for 2013 and 2015 and secondary containment test results for 2015 were not on site. These records shall <br /> be maintained on site for at least three years. Monitoring records include: (1) date and time of all monitoring or <br /> sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br /> results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br /> equipment, ground water elevations, or other test results; (6) results of inventory readings and reconciliations. <br /> Immediately locate and maintain all maintenance and monitoring records for the last three years on site and submit <br /> copies to the EHD. Facility operator called service company and obtained copies of test results. This was corrected <br /> on site. <br /> This is a minor violation. <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br /> An current and approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.