My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2512
>
2300 - Underground Storage Tank Program
>
PR0232418
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:16:02 PM
Creation date
6/23/2020 6:55:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232418
PE
2361
FACILITY_ID
FA0004064
FACILITY_NAME
WATERLOO LIQUOR
STREET_NUMBER
2512
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14128102
CURRENT_STATUS
01
SITE_LOCATION
2512 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232418_2512 E WATERLOO_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
429
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WATERLOO LIQUOR 12512 E WATERLOO RD STOCKTON ]April 20 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to check and note the correct test dates for the secondary containment, monitoring <br /> system certification, leak detector, and spill container testing on the February and March 2015 designated operator <br /> monthly inspection reports. The monitoring system certification, leak detector, and spill container testing were listed <br /> as 4-29-14. These should have been listed as 4-21-14. The secondary containment test was listed as 7-15-12. This <br /> should have been listed as 7-11-12. <br /> The designated operator failed to check and note the correct test dates for the secondary containment, monitoring <br /> system certification, and spill container testing on the August 2014 through January 2015 designated operator monthly <br /> inspection reports. The monitoring system certification and spill container testing were listed as 4-29-14. These should <br /> have been listed as 4-21-14. The secondary containment test was listed as 7-15-12. This should have been listed as <br /> 7-11-12. <br /> The designated operator failed to check and note the correct test dates for the secondary containment testing on the <br /> May through July 2014 designated operator monthly inspection reports. The secondary containment test was listed as <br /> 8-3-11. This should have been listed as 7-11-12. <br /> During the monthly inspection, the designated operator shall check that all required testing and maintenance for the <br /> UST system have been completed and document the dates they were done. Ensure that designated operators <br /> performing monthly inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The diesel line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting a <br /> 3-gallon per hour leak at 10 psi. The leak detector was replaced and retested during the inspection. A"UST Retrofit <br /> Verification with Inspector Already Onsite" form has been completed and provided to the operator and contractor. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 5-20-15. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Received by Inspector: Phone: Date: <br /> (initial): ��r��. �- ARIS VELOSO, Senior REHS (209)468-3453 04/20/2015 <br /> Page 5of6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.